DANSK DSF/PREN IEC 62351-5 PDF

DANSK DSF/PREN IEC 62351-5 PDF

Name:
DANSK DSF/PREN IEC 62351-5 PDF

Published Date:

Status:
[ Draft-Obsolete ]

Description:

Power systems management and associated information exchange – Data and communications security – Part 5: Security for IEC 60870-5 and derivatives

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$20.7
Need Help?
DRAFT * W/D S/S BY DS/EN IEC 62351-5

This part of IEC 62351 defines the application authentication mechanism (A-profile) specifying messages, procedures and algorithms for securing the operation of all protocols based on or derived from IEC 60870-5: Telecontrol Equipment and Systems – Transmission Protocols. This Standard applies to at least those protocols listed in Table 1. [Table 1] The initial audience for this International Standard is intended to be the members of the working groups developing the protocols listed in Table 1. For the measures described in this standard to take effect, they must be accepted and referenced by the specifications for the protocols themselves. This document is written to enable that process. The working groups in charge of take this standard to the specific protocols listed in Table 1 may choose not to do so. The subsequent audience for this specification is intended to be the developers of products that implement these protocols. Portions of this standard may also be of use to managers and executives in order to understand the purpose and requirements of the work. This document is organized working from the general to the specific, as follows: - Clauses 2 through 4 provide background terms, definitions, and references. - Clause 5 describes the problems this specification is intended to address. - Clause 6 describes the mechanism generically without reference to a specific protocol. - Clauses 7 and 8 describe the mechanism more precisely and are the primary normative part of this specification. - Clause 9 define the interoperability requirements for this authentication mechanism. - Clause 10 describes the requirements for other standards referencing this specification Unless specifically labelled as informative or optional, all clauses of this specification are normative.


Edition : 21
File Size : 1 file , 2.6 MB
Number of Pages : 112
Product Code(s) : DSF-061, DSF-061

History

DANSK DSF/FPREN IEC 62351-5
Published Date:
Power systems management and associated information exchange – Data and communications security – Part 5: Security for IEC 60870-5 and derivatives
$20.7
DANSK DSF/PREN IEC 62351-5
Published Date:
Power systems management and associated information exchange – Data and communications security – Part 5: Security for IEC 60870-5 and derivatives
$20.7
DANSK DS/EN IEC 62351-5
Published Date: 03/09/2023
Power systems management and associated information exchange – Data and communications security – Part 5: Security for IEC 60870-5 and derivatives
$42.9

Related products

DANSK DS/EN ISO 3834-2
Published Date: 05/04/2021
Quality requirements for fusion welding of metallic materials – Part 2: Comprehensive quality requirements (ISO 3834-2:2021)
$18
DANSK DS/ISO 6336-2
Published Date: 12/02/2019
Calculation of load capacity of spur and helical gears – Part 2: Calculation of surface durability (pitting)
$30
DANSK DS/EN 60749-34
Published Date: 01/26/2011
Semiconductor devices - Mechanical and climatic test methods - Part 34: Power cycling
$15.3

Best-Selling Products

AABC BASIC-PSYCHROMETRICS
Published Date:
TABpro Training Series Video - Basic Psychrometrics
$57.6
AABC BUNDLE
Published Date:
TABpro Training Series Video - Bundle (VAV, Duct Leakage & Psychrometrics)
$224.7
AABC DIRECTORY
Published Date: 01/01/2011
Directory
AABC DIRECTORY
Published Date: 01/01/2012
Directory
AABC DUCT LEAKAGE
Published Date:
TABpro Training Series Video - Duct Leakage and Pressure Decay Testing
$96
AABC KAHOE FIELD MANUAL
Published Date:
Kahoe Test and Balance Field Manual
$45.6