DNV DNV-RP-F202 PDF

DNV DNV-RP-F202 PDF

Name:
DNV DNV-RP-F202 PDF

Published Date:
10/01/2010

Status:
[ Revised ]

Description:

COMPOSITE RISERS

Publisher:
DNV

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$17.1
Need Help?

Scope and application

This RP provides the design philosophy, loads and global analysis aspects valid for risers made of composite materials. The RP applies to all new built riser systems and may be applied to modification, operation and upgrading of existing risers.

The risers covered in the RP can be jointed or continuous. Bonded rubber risers and risers with un-bonded load bearing structures are not included. Applications are production, drilling and injection risers, as well as choke and kill lines.

Composites are fibre reinforced plastics. The fibres should have a higher modulus than the surrounding polymeric matrix material. The matrix may be thermoset or thermoplastic.

Composite risers have typically internal and external liners around the main pipe section. Any material may be chose for the liners, as long as long term performance of the liners can be demonstrated. Standards related to chosen liner material shall be used to document liner performance. Additional requirements to liners and interfaces are given in Sec.6.

Composite risers have typically metal end flanges. Any material may be chosen for the flanges, as long as long term performance of the flanges can be demonstrated. Standards related to chosen flange material shall be used to document performance of the flanges. Additional requirements to end flanges are given in Sec.6 (composite metal interface).

The scope covers design, materials, fabrication, testing, operation, maintenance and re-assessment of riser systems. Aspects relating to documentation, verification and quality control are also addressed. The main purpose is to cover design and analysis of top tensioned and compliant composite riser systems operated from floaters and fixed platforms. The RP applies for permanent operation (e.g. production and export/ import of hydrocarbons and injection of fluids), as well as for temporary operation (e.g. drilling and completion/ workover activities).

This RP is applicable to structural design of all pressure containing components that comprise the riser system. Other composite components can be designed according to DNVOS- C501.

Guidance note:

Most composite risers of today consist of metallic or polymeric liners within the composite pipes. The purpose of the liners is to prevent leakage of the riser, while the composite pipes are the load carrying part of the riser system. This RP covers risers with (and without) liners as well as riser connectors and other riser components such as tension joints and stress joints.

There are, in principle, no limitations regarding floater type, water depth, riser application and configuration. However, for novel applications where experience is limited, special attention shall be given to identify possible new failure mechanisms, validity/adequacy of analysis methodology and new loads and load combinations.

Guidance note:

Composite risers are novel applications and it shall be documented that the global load effects can be predicted with same precision as for conventional riser systems. This may typically involve validation of computational methodology by physical testing.

As an alternative, an appropriate conservatism in design should be documented.

Procedures of DNV-RP-A203 "Qualification of new technology" should be considered


Edition : 10
File Size : 1 file , 610 KB
Number of Pages : 46
Published : 10/01/2010

History

DNV DNV-RP-F202
Published Date: 10/01/2010
COMPOSITE RISERS
$17.1
DNV DNV-RP-F202
Published Date: 05/01/2003
COMPOSITE RISERS
$17.1
DNV DNV-RP-F202
Published Date: 05/01/2003
COMPOSITE RISERS
$17.1

Related products

DNV DNV TAP NO. MR-A002
Published Date: 01/01/2014
Sensors
$17.1
DNV DNV TAP NO. 844.50-MED A.1/4.2
Published Date: 01/01/2003
MARINE ELECTROMAGNETIC COMPASS
$17.1
DNV DNV-RU-SHIPS PART 6 CHAPTER 2
Published Date: 07/01/2024
Part 6 Additional class notations - Chapter 2 Propulsion, power generation and auxiliary systems
$17.1
DNV DNV TAP NO. MR-E012
Published Date: 07/01/2013
Cable Ties
$17.1

Best-Selling Products

FLBC FLAC CH 11
Published Date: 01/01/2007
2007 FLORIDA BUILDING CODE - Chapter 11 Florida Accessibility Code for Building Construction
$9
FLBC FLAC CH 11
Published Date: 01/01/2007
2007 FLORIDA BUILDING CODE - Chapter 11 Florida Accessibility Code for Building Construction
$9
FLBC FLAC CH 11
Published Date: 01/01/2004
2004 FLORIDA BUILDING CODE - Chapter 11 Florida Accessibility Code for Building Construction
$3
FLBC FLBAC
Published Date: 01/01/2014
2014 FLORIDA BUILDING CODE - Accessibility
$21
FLBC FLBAC
Published Date: 01/01/2020
2020 FLORIDA BUILDING CODE - Accessibility
$21.3
FLBC FLBAC
Published Date: 01/01/2017
2017 FLORIDA BUILDING CODE - Accessibility
$21.6