Name:
DNV DNVGL-RP-J203 PDF
Published Date:
09/01/2019
Status:
[ Revised ]
Publisher:
DNV
General
This RP defines performance requirements and procedures for the following:
— the selection and qualification of geological storage sites for long-term storage of CO2
— the documentation of storage site characterization and storage site development plans as a basis for permit applications/reviews
— risk management throughout life cycle of CO2 geological storage projects, from initial screening and storage site selection through to storage site closure and preparation for post-closure stewardship
— monitoring and storage performance verification
— well assessment and management planning
— storage site closure and preparation for post-closure stewardship.
Where the term CO2 is used in the guideline, it assumes that carbon dioxide is pressurized; may or may not contain water; exists either as a liquid, super critical fluid or a gas; and also includes carbon dioxide dissolved in water contained in the injection zone.
Qualification requirements
The following qualification requirements are summarized in tables throughout the document:
- Table 4-1: Requirements to potential storage sites that should be included in the screening basis.
- Table 4-3: Requirements to prospective storage sites that shall be included in the appraisal basis (in addition those listed in Table 4-1).
- Table 5-2: Requirements for storage site closure.
- Table 5-3: Requirements for the storage development plan.
- Table 5-1: Requirements for the monitoring plan.
Exclusions
This RP does not include performance requirements or recommended procedures for:
— the selection and qualification of hydrocarbon fields for enhanced recovery by CO2 injection
— the capture of CO2 and its transportation from source to storage site
— management of surface facilities and well operations (injection wells, production wells, monitoring wells)
— accounting of CO2 emissions avoided
— CO2 injection and storage in un-mineable coal beds, basalt formations, shales, and salt caverns
— underground storage in materials involving the use of any form of engineered containers.
Application
This RP may be applied as a basis for verification and risk-based decision making, including but not limited to:
— guidance and quality assurance of storage site planning and development
— demonstration of compliance with industry best practice
— implementation of regulations
— independent assessment and verification
— stakeholder communication.
The requirements in this RP shall be subordinate to local regulations.
| Edition : | 19 |
| File Size : | 1 file , 990 KB |
| Number of Pages : | 74 |
| Published : | 09/01/2019 |