ECIA TEP197-A PDF

ECIA TEP197-A PDF

Name:
ECIA TEP197-A PDF

Published Date:
10/01/1997

Status:
[ Active ]

Description:

Preparation of X-Radiation Characteristic Curves for Cathode Ray Tubes

Publisher:
Electronic Components Industry Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
ecia-tep197-a_2584835

Choose Document Language:
37.50 €
Need Help?

Introduction

In accordance with the Radiation Control for the Health and Safety Act of 1968, cathode ray tube (CRT) manufacturers are required to submit an initial report to the Center for Devices and Radiological Health (CDRH), an agency of the U.S. Department of Health and Human Services (DHHS). The initial report for cathode ray tubes must provide results of the testing and measuring of the X-radiation emissions from a cathode ray tube.

The initial report for a new CRT tube is submitted by a manufacturer. The parts of the initial report to be discussed by this document are the preparation of the data plots for X-radiation limit curves and 36 pAikg isoexposure-rate limit curves. The X-radiation limit cuwe defines the relationship between CRT highvoltage and the X-radiation exposure rate (pNkg) under a constant beam current. The "36 pNkg isoexposure rate limit curve" defines the combinations of CRT anode voltages and beam currents that produce a constant rate, in this case 36 pAikg, of X-radiation emission from the CRT. Usually, such limit curves represent the worst case conditions for X-radiation emission from the CRT. Pertinent parameters to be reported are the registration reference points and limit curve slope factors.

Throughout this document the terms ''CRT high-voltage" and "anode voltage" mean the overall acceleration of the electron beam from cathode to final anode.

Two limit curves should be developed, one for the entire CRT and one for the anode contact. The following instruction for the preparation of the X-radiation characteristic curves is recommended to insure uniformity throughout the CRT industry.

NOTE—TO conform with the International System of Units (SI) dimensions, the unit for radiation exposure of "pA4g" (picoamperes per kilogram) has replaced "mWh". The SI equivalent of 0.5 mWh is 36 piükg. The relationship between the two measurements scales is:

1 mWh = 72 pNkg


Edition : A
File Size : 1 file , 770 KB
Number of Pages : 21
Published : 10/01/1997

History


Related products

ECIA EIA-359-A
Published Date: 01/01/1985
Standard Colors for Color Identification and Coding
25.50 €
ECIA EIA-364-57A
Published Date: 08/01/2017
TP-57A Coupling Pin Strength Test Procedure for Circular Bayonet Electrical Connectors
22.50 €
ECIA EIA-364-99
Published Date: 01/01/1999
TP-99 Gage Location and Retention Test Procedure for Electrical Connectors
22.50 €
ECIA SP4524
Published Date: 03/15/1999
Firewall Flame Test Procedure for Electrical Connectors
2.40 €

Best-Selling Products

IETF 8254-2
Published Date: 07/01/2016
Papiers et cartons - Mesurage du brillant spéculaire - Partie 2: Brillant à 75° avec un faisceau parallèle, méthode DIN
24.30 €
IETF FAA AC 43-10
Published Date: 02/01/1983
MECHANICAL WORK PERFORMED ON U.S. AND CANADIAN REGISTERED AIRCRAFT
IETF RFC 1000
Published Date: 08/01/1987
The Request for Comments Reference Guide
21.00 €
IETF RFC 1002
Published Date: 03/01/1987
PROTOCOL STANDARD FOR A NetBIOS SERVICE ON A TCP/UDP TRANSPORT: DETAILED SPECIFICATIONS
18.30 €
IETF RFC 1014
Published Date: 06/01/1987
XDR: EXTERNAL DATA REPRESENTATION STANDARD
IETF RFC 1042
Published Date: 02/01/1988
A Standard for the Transmission of IP Datagrams over IEEE 802 Networks
10.20 €