HI 9.8-2012 PDF

HI 9.8-2012 PDF

Name:
HI 9.8-2012 PDF

Published Date:
2012

Status:
Active

Description:

Intake Design For Rotodynamic Pumps

Publisher:
Hydraulic Institute

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
hi-9-8-2012_1850273

Choose Document Language:
72.00
Need Help?
The 2012 version of the Pump Intake Design Standard is a completely updated and expanded version of the widely respected Intake Design standard issued in 1998. Developed by experts in sump design, researchers specialized in fluid flow dynamics, and senior engineers representing pump manufacturers and the end user community, this standard enables designers, owners, and users to configure functional pumping facility designs and provides remedial measures for problem intakes.

Ideally, the flow of liquid into any pump should be uniform, steady, and free from swirl and entrained air. Lack of uniformity can cause the pump to operate away from the optimum design condition and at a lower hydraulic efficiency. This standard addresses specific phenomena that can adversely affect the performance of pumps, including:
  • Submerged vortices
  • Free surface vortices
  • Preswirl magnitude and fluctuation with time
  • Nonuniform distribution of velocity in space and time at the impeller eye
  • Entrained air or gas bubbles


The standard provides a flowchart to serve as a guide to the use of this standard and can be used to locate the appropriate section(s) in the standard. The following types of intakes are included in this standard: Rectangular intakes
  • Formed suction intakes
  • Circular pump stations
  • Trench-type intakes for clear liquids and for solids-bearing liquids
  • Tanks - pump suction
  • Can vertical turbine pump intakes
  • Unconfined intakes
  • Circular plan wet pit for solids-bearing liquids


Other topics of interest in this standard include:
  • Physical model studies of intake structures and when they are necessary
  • Inlet bell design
  • Required submergence for minimizing surface vortices
  • Computational fluid dynamics (CFD)
  • Performance enhancements for trench-type wet wells Alternate formed suction intake designs

ANSI : ANSI Approved
File Size : 1 file , 4.4 MB
ISBN(s) : 1880952702
Note : This product is unavailable in Russia, Belarus
Number of Pages : 132
Published : 2012

History

HI 9.8-2018
Published Date: 2018
Rotodynamic Pumps for Pump Intake Design
78.00 €
HI 9.8-2012
Published Date: 2012
Intake Design For Rotodynamic Pumps
72.00 €
HI 9.8 (M123)
Published Date: 01/01/1998
American National Standard for Centrifugal and Vertical Pump Intake Design
72.00 €

Related products

HI 9.1-9.5-2021
Published Date: 09/28/2021
Pumps - General Guidelines for Types, Applications, Definitions, Sound Measurements, and Documentation
25.50 €
HI 9.6.5-2022
Published Date: 2022
American National Standard for Rotodynamic Pumps - Guideline for Condition Monitoring
27.00 €
HI 9.6.7-2021
Published Date: 09/01/2021
Rotodynamic Pumps - Guideline for Effects of Liquid Viscosity on Performance
49.50 €
HI 9.6.6-2022
Published Date: 2022
Rotodynamic Pumps for Pump Piping
49.50 €

Best-Selling Products

AENOR EA 0007
Published Date: 09/07/2016
Requisitos del sistema de seguimiento y agregación de los precios del papel para reciclar.
12.90 €
AENOR EA 0014
Published Date: 02/14/2003
Marcado por impresión de los elementos calefactores que utilizan cable calefactor según la Norma UNE 21155-1.
5.40 €
AENOR EA 0032
Published Date: 07/11/2007
Equipos estabilizadores de tensión y reductores de flujo luminoso en cabecera de línea. Requisitos generales y de seguridad
23.70 €
AENOR EA 0039
Published Date: 02/04/2009
Cables multiconductores de tensión asignada 0,6/1 kV no propagadores del incendio, aislados con polietileno reticulado y con cubierta de poliolefina, para utilizar como instalación fija en circuitos de control.
18.90 €
AENOR EA 0042
Published Date: 12/23/2014
Aparamenta de baja tensión. Equipos auxiliares. Conjuntos de bloques de conexión para la verificación de contadores de energía.
22.20 €
AENOR EA 0051
Published Date: 12/23/2014
Cables eléctricos de distribución con aislamiento extruido, de tensión asignada desde 3,6/6 (7,2) kV hasta 20,8/36 (42) kV inclusive. Cables unipolares y unipolares reunidos con aislamiento de HPTE. Cables con cubierta de compuesto de poliolefina (tipo 1, tipo 2 y tipo 3)
22.20 €