IEC 60079-13 Ed. 2.0 en:2017 PDF

IEC 60079-13 Ed. 2.0 en:2017 PDF

Name:
IEC 60079-13 Ed. 2.0 en:2017 PDF

Published Date:
05/22/2017

Status:
Active

Description:

Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"

Publisher:
International Electrotechnical Commission

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$83.4
Need Help?
IEC 60079-13:2017(E) gives requirements for the design, construction, assessment, verification and marking of rooms used to protect internal equipment by pressurization or artificial ventilation or both as applicable when located in an explosive gas atmosphere or combustible dust atmosphere hazardous area with or without an internal source of a flammable gas or vapour. It also includes a room located in a non-hazardous area that has an internal source of release of a flammable gas or vapour. This document deals with rooms that are partially constructed in a manufacturer’s facility and intended to have the final installation completed on-site, as well as rooms that are constructed completely on-site. Rooms partially constructed in a manufacturer’s facility may include third-party verification. For rooms built on-site, this document can be used by plant operators as a guide for assessment of those facilities. This document represents a major technical revision of the requirements for equipment protection by pressurized room "p" and artificially ventilated room "v" and should be considered as introducing all new requirements. This second edition cancels and replaces the first edition published in 2010. This edition constitutes a technical revision.  This edition includes the following significant technical changes with respect to the previous edition:
- modification of the title of this document to include artificially ventilated room "v" in addition to pressurized room "p";
- addition of types of protection "pb", "pc", and "vc" and removal of types of protection "px", "py", "pz" and "pv";
- definition of the differences between pressurization and artificial ventilation types of protection;
- removal of protection of rooms with an inert gas or a flammable gas from the scope of this document;
- addition of an informative annex to include examples of applications where types of protection pressurization or artificial ventilation or pressurization and artificial ventilation can be used and associated guidelines. Additional information regarding the scope of this document can be found in Clause 1.
Edition : 2.0
File Size : 1 file , 580 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 35
Published : 05/22/2017

History

IEC 60079-13 Ed. 2.0 b:2017
Published Date: 05/22/2017
Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
$83.4
IEC 60079-13 Ed. 2.0 en:2017
Published Date: 05/22/2017
Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
$83.4
IEC 60079-13 Ed. 1.0 b:2010
Published Date: 10/05/2010
Explosive atmospheres - Part 13: Equipment protection by pressurized room "p"
$70.5

Related products

IEC 62013-2 Ed. 2.0 b:2005
Published Date: 10/24/2005
Caplights for use in mines susceptible to firedamp - Part 2: Performance and other safety-related matters
$19.2
IEC 61241-2-1 Ed. 1.0 b:1994
Published Date: 12/21/1994
Electrical apparatus for use in the presence of combustible dust - Part 2: Test methods - Section 1: Methods for determining the minimum ignition temperatures of dust
$69
IEC 60079-2 Ed. 6.0 b:2014
Published Date: 07/21/2014
Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure "p"
$125.1
IEC 60079-17 Ed. 6.0 b:2023
Published Date: 12/01/2023
Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
$98.7

Best-Selling Products