Description:

Explosive atmospheres – Part 14: Electrical installation design, selection and installation of equipment, including initial inspection

Publisher:
International Electrotechnical Commission

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$154.5
Need Help?

This part of IEC 60079 contains the specific requirements for the design of electrical systems, selection, installation and the required initial inspection of electrical installations of Ex Equipment in, or associated with, explosive atmospheres including requirements for documentation and personnel competency.

These requirements are in addition to the requirements for installations in non-hazardous areas.

NOTE 1 For voltages up to 1 000 V AC or 1 500 V DC requirements of this document are based on installation requirements in the IEC 60364 series and for higher voltages in the IEC 61936 series, but other relevant national requirements can apply. For offshore, the IEC 61892 series is applicable.

NOTE 2 Maximum voltages are limited by specific Types of Protection according to other parts of the IEC 60079 series and will be given in the documentation for the Ex Equipment.

This document applies to all electrical Ex Equipment including fixed, transportable, portable and personal, and installations, permanent or temporary.

NOTE 3 Guidance on transportable, portable or personal equipment can be found in Annex I and IEC TS 60079-48.

This document does not apply to:
• electrical installations in mines susceptible to firedamp;
NOTE 4 This document might apply to electrical installations in mines where explosive gas atmospheres other than firedamp can be formed and to electrical installations in the surface installation of mines.
• inherently explosive situations and dust from explosives or pyrophoric substances (for example explosives manufacturing and processing);
• rooms used for medical purposes;
• electrical installations in areas where the hazard is due to flammable mist; and
• installation of non-electrical Ex Equipment (unless being part of an equipment assembly according IEC TS 60079-46).

NOTE 5 Additional guidance on the requirements for hazards due to hybrid mixtures of dust or flyings and flammable gas or vapour is provided in Annex H.

NOTE 6 The use of portable tools having an Ex Equipment certificate might introduce an ignition source which is beyond the scope of this document, for example: a drill which could create a high temperature at the work piece.

No account is taken in this document of the toxic hazards that are associated with flammable gases, liquids and dusts in concentrations that are usually very much less than the lower flammable limit. In locations where personnel could be exposed to potentially toxic concentrations of flammable material, appropriate precautions are necessary. Such precautions are outside the scope of this document.


Edition : 6.0
File Size : 1 file , 5.8 MB
ISBN(s) : 9782832293003
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 304
Published : 08/01/2024

History

IEC 60079-14 Ed. 6.0 b:2024
Published Date: 08/01/2024
Explosive atmospheres – Part 14: Electrical installation design, selection and installation of equipment, including initial inspection
$154.5
IEC 60079-14 Ed. 5.0 b:2013
Published Date: 11/28/2013
Explosive atmospheres - Part 14: Electrical installations design, selection and erection
$144.3
IEC 60079-14 Ed. 4.0 b:2007
Published Date: 12/13/2007
Explosive atmospheres - Part 14: Electrical installations design, selection and erection
$99
IEC 60079-14 Ed. 3.0 b:2002
Published Date: 10/24/2002
Electrical apparatus for explosive gas atmospheres - Part 14: Electrical installations in hazardous areas (other than mines)
$55.2

Related products

IEC 60079-4A Ed. 1.0 b:1970
Published Date: 01/01/1970
Electrical apparatus for explosive gas atmospheres - Part 4: Method of test for ignition temperature - First supplement. *Note.-This supplement applies also to the second edition of 1975
$5.7
IEC 60079-26 Ed. 4.0 b:2021
Published Date: 02/25/2021
Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga
$57
IEC 60079-27 Ed. 2.0 b:2008
Published Date: 01/30/2008
Explosive atmospheres - Part 27: Fieldbus intrinsically safe concept (FISCO)
$18.9

Best-Selling Products

IEC/TS 60034-16-2 Ed. 1.0 b:1991
Published Date: 02/15/1991
Rotating electrical machines - Part 16: Excitation systems for synchronous machines - Chapter 2: Models for power system studies
$33
IEC/TS 60034-16-3 Ed. 1.0 b:1996
Published Date: 02/14/1996
Rotating electrical machines - Part 16: Excitation systems for synchronous machines - Section 3: Dynamic performance
$43.5
IEC/TS 60034-17 Ed. 3.0 b:2002
Published Date: 03/26/2002
Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide
$18.3
IEC/TS 60034-17 Ed. 4.0 b:2006
Published Date: 05/09/2006
Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide
$47.1
IEC/TS 60034-18-32 Ed. 1.0 b:1995
Published Date: 03/29/1995
Rotating electrical machines - Part 18: Functional evaluation of insulation systems - Section 32: Test procedures for form-wound windings - Electrical evaluation of insulation systems used in machines up to and including 50 MVA and 15 kV
$18.3
IEC/TS 60034-18-33 Ed. 1.0 b:1995
Published Date: 03/29/1995
Rotating electrical machines - Part 18: Functional evaluation of insulation systems - Section 33: Test procedures for form-wound windings - Multifactor functional evaluation - Endurance under combined thermal and electrical stresses of insulation systems used in machines up to and including 50 MVA a
$32.1