IEC 60099-8 Ed. 2.0 en:2017 PDF

IEC 60099-8 Ed. 2.0 en:2017 PDF

Name:
IEC 60099-8 Ed. 2.0 en:2017 PDF

Published Date:
11/14/2017

Status:
Active

Description:

Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV

Publisher:
International Electrotechnical Commission

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$125.1
Need Help?
IEC 60099-8:2017 covers metal-oxide surge arresters with external series gap (externally gapped line arresters (EGLA)) that are applied on overhead transmission and distribution lines, only to protect insulator assemblies from lightning-caused flashovers.A This document defines surge arresters to protect the insulator assembly from lightning-caused over-voltages only. Therefore, and since metal-oxide resistors are not permanently connected to the line, the following items are not considered for this document:
- switching impulse spark-over voltage;
- residual voltage at steep current and switching current impulse;
- thermal stability;
- long-duration current impulse withstand duty;
- power-frequency voltage versus time characteristics of an arrester;
- disconnector test;
- aging duties by power-frequency voltage.
Considering the particular design concept and the special application on overhead transmission and distribution lines, some unique requirements and tests are introduced, such as the verification test for coordination between insulator withstand and EGLA protective level, the follow current interrupting test, mechanical load tests, etc. Designs with the EGLA's external series gap installed in parallel to an insulator are not covered by this document. This second edition cancels and replaces the first edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
The Lightning discharge capability test has been completely re-written and re-named to Test to verify the repetitive charge transfer rating, Qrs with lightning discharges to reflect changes introduced in IEC 60099-4 Ed.3 (2014) regarding new methods for rating the energy and charge handling capability of metal-oxide arresters. In addition to testing to evaluate the performance of the MO resistors, procedures for evaluating the performance of the EGLA series gaps have been introduced.
- Omissions from Ed. 1 of this standard have been included, notably an RIV test and a means for determining the thermal time constant of the SUV portion of the EGLA.
- Definitions for new terms have been added
- A number of NOTES in Ed. 1 have been converted to normative requirements

Keywords: externally gapped line arresters (EGLA), lightning-caused over-voltages
Edition : 2.0
File Size : 1 file , 1.3 MB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 137
Published : 11/14/2017

History

IEC 60099-8 Ed. 2.0 b:2018
Published Date: 11/14/2017
Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV
$105.6
IEC 60099-8 Ed. 2.0 en:2017
Published Date: 11/14/2017
Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV
$125.1
IEC 60099-8 Ed. 2.0 b:2017
Published Date: 11/14/2017
Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV
$125.1
IEC 60099-8 Ed. 1.0 b:2011
Published Date: 01/27/2011
Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV
$105.6

Related products

IEC 61330 Ed. 1.0 b:1995
Published Date: 12/05/1995
High-voltage/low voltage prefabricated substations
$41.7
IEC 61643-11 Ed. 1.0 b:2011
Published Date: 03/09/2011
Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods
$136.5

Best-Selling Products

IPC 0040
Published Date: 05/01/2003
Optoelectronics Assembly and Packaging Technology
$51.9
IPC 1071
Published Date: 12/01/2010
Best Industry Practices for Intellectual Property Protection in Printed Board Manufacturing
$29.1
IPC 1071A
Published Date: 08/01/2014
Best Industry Practices for Intellectual Property Protection in Printed Board Manufacturing
$29.1
IPC 1131
Published Date: 04/01/2000
Information Technology Guide for PWB Manufacturers
$29.1