IEC 60229 Ed. 3.0 b:2007 PDF

IEC 60229 Ed. 3.0 b:2007 PDF

Name:
IEC 60229 Ed. 3.0 b:2007 PDF

Published Date:
10/10/2007

Status:
Active

Description:

Electric cables - Tests on extruded oversheaths with a special protective function

Publisher:
International Electrotechnical Commission

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$15.3
Need Help?
Provides a range of tests which may be required for electric cables which have an extruded oversheath and where that oversheath performs a special protective function. The standard covers cables for use in insulated systems and in uninsulated systems. The tests are categorized for use as routine tests, type tests and tests after installation. These tests comprise of electrical routine tests on cable oversheath used in insulated or uninsulated systems, abrasion and corrosion spread type tests, electrical test on cable oversheath after installation. Routine tests and tests after installation, as specified in the relevant cable standards, are applicable for all situations. Type tests depend upon the nature of the system and the construction of the cable and do not have to be carried out for normal conditions of use. The significant technical changes with respect to the previous edition are as follows: - The text has been modified in order to consider the function of the oversheath, irrespective of the way the metallic sheath or screen of the cable is earthed because, in some cases, the oversheath is designed to act not only as a protection against corrosion, but also to reduce the risk of degradation of the cable insulation system. This requirement may be independent of the nature of the insulation and independent of the rated voltage of the cable. - More precise wording has been introduced regarding the application of some tests (if the sheaths or foils are bonded to the oversheath or not). - The test requirements have been revised in order to be in line with the standards published after the second edition. - The pressure test at high temperature has been deleted as the requirement is specified in the relevant cable standards. - A "Guidance on tests after installation" (Annex B) has been included.
Edition : 3.0
File Size : 1 file , 890 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 22
Published : 10/10/2007

History

IEC 60229 Ed. 3.0 b:2007
Published Date: 10/10/2007
Electric cables - Tests on extruded oversheaths with a special protective function
$15.3
IEC 60229 Ed. 2.0 b:1982
Published Date: 01/01/1982
Tests on cable oversheaths which have a special protective function and are applied by extrusion
$9

Related products

IEC 60173 Ed. 1.0 b:1964
Published Date: 01/01/1964
Colours of the cores of flexible cables and cords
$5.7
IEC 60332-1-3 Ed. 1.0 b:2004
Published Date: 07/15/2004
Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles
$15.3
IEC 60189-3 Ed. 4.0 en:2007
Published Date: 05/23/2007
Low-frequency cables and wires with PVC insulation and PVC sheath - Part 3: Equipment wires with solid or stranded conductor wires, PVC insulated, in singles, pairs and triples
$28.5
IEC 60092-354 Ed. 4.0 b:2020
Published Date: 02/06/2020
Electrical installations in ships ¿¿¿ Part 354: Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)
$43.5

Best-Selling Products

AAMI/ISO 10993-1:2003
Published Date: 12/01/2003
Biological Evaluation of Medical Devices Part 1: Evaluation and Testing
$26.4
AAMI/ISO 10993-1:2009 Erratum
Published Date: 06/10/2013
Erratum for Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
Free Download
AAMI/ISO 10993-1:2009/(R)2013
Published Date: 09/03/2009
Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process; Includes Erratum (2013)
AAMI/ISO 10993-1:2018
Published Date: 04/27/2020
Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
$82.5
AAMI/ISO 10993-10:2010/(R)2014
Published Date: 09/04/2010
Biological evaluation of medical devices - Part 10: Tests for irritation and skin sensitization
$82.5
AAMI/ISO 10993-11:2006/(R)2014
Published Date: 10/19/2006
Biological evaluation of medical devices - Part 11: Tests for systemic toxicity