Description:

Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)

Publisher:
International Electrotechnical Commission

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$106.2
Need Help?
Specifies the construction, dimensions and test requirements of power cables with extruded solid insulation for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV) for fixed installations such as distribution networks or industrial installations. This standard includes cables which exhibit properties of reduced flame spread, low levels of smoke emission and halogen-free gas emission when exposed to fire. Cables for special installation and service conditions are not included, for example cables for overhead networks, the mining industry, nuclear power plants (in and around the containment area), submarine use or shipboard application. The main changes with respect to the first edition relate to insulation and oversheath thickness requirements, and inclusion of constructions and requirements for halogen free cables with reduced flame propagation and low levels of smoke emission.
Edition : 2.0
File Size : 1 file , 860 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 115
Published : 04/14/2004

History

IEC 60502-1 Ed. 3.0 en:2021
Published Date: 02/09/2021
Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV(Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)
$110.1
IEC 60502-1 Ed. 2.1 b:2009
Published Date: 11/25/2009
Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV(Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV) CONSOLIDATED
$132.9
IEC 60502-1 Ed. 2.0 b:2004
Published Date: 04/14/2004
Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)
$106.2

Related products

IEC 60331-21 Ed. 1.0 b:1999
Published Date: 04/28/1999
Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements - Cables of rated voltage up to and including 0,6/1,0 kV
$15.3
IEC 60754-1 Ed. 3.1 b:2019
Published Date: 11/25/2019
Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content CONSOLIDATED EDITION
$81.6
IEC 60287-1-3 Ed. 2.0 en:2023
Published Date: 05/01/2023
Electric cables - Calculation of the current rating - Part 1-3: Current rating equations (100 % load factor) and calculation of losses - Current sharing between parallel single-core cables and calculation of circulating current losses
$57
IEC 60331-1 Ed. 2.0 b:2018
Published Date: 03/28/2018
Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830 ¿¿C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm
$70.2

Best-Selling Products

TBK 1-2:1994
Published Date: 06/01/1994
General rules for presssure vessels
TBK 5-6:1996
Published Date: 06/01/1996
General rules for piping systems