Description:

Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)

Publisher:
International Electrotechnical Commission

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$105.3
Need Help?
Specifies the construction, dimensions and test requirements of power cables with extruded solid insulation from 6 kV up to 30 kV for fixed installations such as distribution networks or industrial installations. When determining applications, it is recommended that the possible risk of radial water ingress is considered. Cable designs with barriers claimed to prevent longitudinal water penetration and an associated test are included in this part of IEC 60502. Cables for special installation and service conditions are not included, for example cables for overhead networks, the mining industry, nuclear power plants (in and around the containment area) nor for submarine use or shipboard application. Significant technical changes with respect to the first edition have been made. The changes relate to possible water ingress, large conductor sizes, partial discharge requirements, insulation and oversheath thickness requirements, range of type approval, electrical tests after installation and tabulated current ratings.
Edition : 2.0
File Size : 1 file , 1.6 MB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 157
Published : 03/08/2005

History

IEC 60502-2 Ed. 3.1 En:2024
Published Date: 05/01/2024
Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) CONSOLIDATED EDITION
$309
IEC 60502-2 Ed. 3.0 b:2014
Published Date: 02/20/2014
Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)
$125.1
IEC 60502-2 Ed. 2.0 b:2005
Published Date: 03/08/2005
Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)
$105.3

Related products

IEC 60050-461 Ed. 2.0 b:2008
Published Date: 06/11/2008
International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
$125.1
IEC 60255-3 Ed. 2.0 b:1989
Published Date: 06/30/1989
Electrical relays - Part 3: Single input energizing quantity measuring relays with dependent or independent time
$15.3
IEC 62271-102 Ed. 2.1 b:2022
Published Date: 04/01/2022
High-voltage switchgear and controlgear - Part 102: Alternating current disconnectors and earthing switches CONSOLIDATED EDITION
$174.6

Best-Selling Products

ANSI/ANSLG C78.21-2003
Published Date:
American National Standard for Electric Lamps - PAR and R Shapes
$66.9
ANSI/ANSLG C78.357-2010
Published Date: 02/15/2011
For incandescent lamps: Tungsten Halogen Lamps (non-vehicle)
$81.6
ANSI/ANSLG C78.377-2011
Published Date: 10/06/2011
American National Standard for Specifications for the Chromaticity of Solid State Lighting (SSL) Products
$33.9
ANSI/ANSLG C78.380-2002
Published Date: 2002
High Intensity Discharge Lamps - Method of Designation
$26.4
ANSI/ANSLG C78.380-2007
Published Date: 2007
American National Standard for Electric Lamps - High-Intensity Discharge (HID) - Method of Designation
$26.4
ANSI/ANSLG C78.40-1992 (R2003)
Published Date:
American National Standard for Mercury Lamps - Specifications
$70.8