IEC 60728-2 Ed. 3.0 en:2018 PDF

IEC 60728-2 Ed. 3.0 en:2018 PDF

Name:
IEC 60728-2 Ed. 3.0 en:2018 PDF

Published Date:
01/10/2018

Status:
Active

Description:

Cable networks for television signals, sound signals and interactive services - Part 2: Electromagnetic compatibility for equipment

Publisher:
International Electrotechnical Commission

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$110.1
Need Help?
IEC 60728-2:2018(E) applies to the radiation characteristics and immunity to electromagnetic disturbance of EM active equipment (active and passive equipment) for the reception, processing and distribution of television, sound and interactive multimedia signals as dealt with in IEC 60728-3, IEC 60728-4, IEC 60728-5 and IEC 60728-6.
This document covers the following frequency ranges:
- disturbance voltage injected into the mains: 150 kHz to 30 MHz;
- radiation from active equipment: 5 MHz to 25 GHz;
- immunity of active equipment: 150 kHz to 25 GHz;
- screening effectiveness of passive equipment: 5 MHz to 3,5 GHz.
This document specifies requirements for maximum allowed radiation, minimum immunity and minimum screening effectiveness and describes test methods for conformance testing.
This third edition cancels and replaces the second edition published in 2010. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Frequency extensions:
a.1) The upper frequency limit of conventional cable network equipment was extended from 862 MHz to 1 000 MHz due to market demands.
a.2) The first intermediate frequency range (1st IF range) for satellite signal transmission was extended to cover now frequencies from 950 MHz up to 3 500 MHz.
a.3) The methods of measurement and the EMC requirements in the overlapping frequency range from 950 MHz to 1 000 MHz were allocated in relation to the upper frequency limit, 1 000 MHz, and the lower frequency limit, 950 MHz, of the relevant equipment under test.
b) New EMC environment in the 800 MHz band:
b.1) The European Commission has requested CENELEC and ETSI to draft immunity requirements for equipment, to protect against disturbance from the new wireless service in the 790 MHz to 862 MHz band.
b.2) A CENELEC/ETSI Joint Working Group a??Digital Dividenda?? was formed to describe the new EMC environment and to advise on appropriate test methods and limits.
b.3) IEC 60728-2 is the document specifying immunity requirements for active and passive cable network equipment.
b.4) The method of measurement and the requirements for in-band immunity were extended taking into account this new EMC environment due to the allocation of broadband wireless services in the frequency band 694 MHz to 862 MHz. As a consequence, the limits of in-band immunity were specified for analogue and additionally for digital signals in this frequency range.
b.5) Consequently it is recommended, that, where cable networks and wireless networks coexist, only the transmission of digitally modulated signals should be used in the frequency range 694 MHz to 862 MHz.
b.6) For passive equipment, Class A and Class B specifications were kept in the standard but a note was added recommending that only Class A equipment should be used in the planning and implementation of new networks.
c) The methods of measurement for all kinds of indoor antennas were combined in the new 4.9.
d) A Bibliography has been added at the end of the document referencing, for example, CEPT Report 30 on a??The identification of common and minimal (least restrictive) technical conditions for 790-862 MHz for the digital dividend in the European Uniona??.
Edition : 3.0
File Size : 1 file , 990 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 56
Published : 01/10/2018

History

IEC 60728-2 Ed. 3.0 en:2018
Published Date: 01/10/2018
Cable networks for television signals, sound signals and interactive services - Part 2: Electromagnetic compatibility for equipment
$110.1
IEC 60728-2 Ed. 2.0 en:2010
Published Date: 01/21/2010
Cable networks for television signals, sound signals and interactive services - Part 2: Electromagnetic compatibility for equipment
$95.1
IEC 60728-2 Ed. 1.0 en:2002
Published Date: 10/22/2002
Cabled distribution systems for television and sound signals - Part 2: Electromagnetic compatibility for equipment
$53.7

Related products

IEC 61603-8-1 Ed. 1.0 b:2003
Published Date: 11/04/2003
Transmission of audio and/or video and related signals using infrared radiation - Part 8-1: Digital audio and related signals
$98.7
IEC 62731 Ed. 2.0 en:2018
Published Date: 01/10/2018
Text-to-speech for television - General requirements
$43.5
IEC 60728-14 Ed. 1.0 b:2014
Published Date: 03/07/2014
Cable networks for television signals, sound signals and interactive services - Part 14: Optical transmission systems using RFoG technology
$110.1

Best-Selling Products

ISO/TR 10013:2001
Published Date: 07/15/2001
Guidelines for quality management system documentation
$33.3
ISO/TR 10014:1998
Published Date: 08/01/1998
Guidelines for managing the economics of quality
$15.9
ISO/TR 10017:2003
Published Date: 05/15/2003
Guidance on statistical techniques for ISO 9001:2000
$44.7
ISO/TR 10064-1:1992
Published Date: 02/01/1992
Cylindrical gears - Code of inspection practice - Part 1: Inspection of corresponding flanks of gear teeth
$55.5
ISO/TR 10064-1:2017
Published Date: 07/01/2017
Code of inspection practice - Part 1: Measurement of cylindrical gear tooth flanks
$69.6
ISO/TR 10064-1:2019
Published Date: 10/01/2019
Code of inspection practice - Part 1: Measurement of cylindrical gear tooth flanks
$83.4