IEC 60806 Ed. 2.0 b:2022 PDF

IEC 60806 Ed. 2.0 b:2022 PDF

Name:
IEC 60806 Ed. 2.0 b:2022 PDF

Published Date:
11/01/2022

Status:
Active

Description:

Determination of the maximum symmetrical radiation field of X-ray tube assemblies and X-ray source assemblies for medical diagnosis

Publisher:
International Electrotechnical Commission

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$15.3
Need Help?

This document is applicable to X-RAY SOURCE ASSEMBLIES and X-RAY TUBE ASSEMBLIES.

NOTE 1 If, for certain MEDICAL ELECTRICAL SYSTEMS, special radiation fields are required such that the scope of IEC 60806 does not apply (e. g., using CT collimators with bow-tie filters), the appropriate system particular standard applies.

This document specifies a method for the determination of the greatest geometrically symmetrical RADIATION FIELD at a specified distance from the FOCAL SPOT for which the percentage AIR KERMA RATE along the major axes of the RADIATION FIELD does not fall below a permitted value.

NOTE 2 In practical use AIR KERMA or AIR KERMA RATE are the most practical physical measures to quantify X-RAY PATTERNS.

In case multiple FOCAL SPOTS are not super-imposed, each FOCAL SPOT has its own REFERENCE AXIS. Then the maximum RADIATION FIELD can be given for each FOCAL SPOT separately.

NOTE 3 The maximum symmetrical RADIATION FIELD can change from its initial value as the X RAY TUBE ages through use.


Edition : 2.0
File Size : 1 file , 1.2 MB
ISBN(s) : 9782832260951
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 26
Published : 11/01/2022

History

IEC 60806 Ed. 2.0 b:2022
Published Date: 11/01/2022
Determination of the maximum symmetrical radiation field of X-ray tube assemblies and X-ray source assemblies for medical diagnosis
$15.3
IEC 60806 Ed. 1.0 b:1984
Published Date: 01/01/1984
Determination of the maximum symmetrical radiation field from a rotating anode X-ray tube for medical diagnosis
$15.3

Related products

IEC 61223-2-7 Ed. 1.0 en:1999
Published Date: 09/16/1999
Evaluation and routine testing in medical imaging departments - Part 2-7: Constancy tests - Equipment for intra-oral dental radiography excluding dental panoramic equipment
$32.1
IEC 61675-3 Ed. 1.0 b:1998
Published Date: 02/26/1998
Radionuclide imaging devices - Characteristics and test conditions - Part 3: Gamma camera based wholebody imaging systems
$10.8

Best-Selling Products

AHAM AC-1-2006
Published Date: 2006
Air Cleaners - Portable - CADR
$30
AHAM AC-1-2018
Published Date: 2018
Method for Measuring Performance of Portable Household Electric Room Air Cleaners
$33
AHAM AC-1-2020
Published Date: 12/14/2020
Method for Measuring Performance of Portable Household Electric Room Air Cleaners
$33
AHAM AC-2-2006 (R2016)
Published Date: 2006
Method for Sound Testing of Portable Household Electric Room Air Cleaners
$12
AHAM AC-3-2009
Published Date: 2009
Room Air Cleaners
$12
AHAM AC-4-2022
Published Date: 07/22/2022
Method of Assessing the Reduction Rate of Chemical Gases by a Room Air Cleaner
$60