IEC 61472 Ed. 2.0 b:2004 PDF

IEC 61472 Ed. 2.0 b:2004 PDF

Name:
IEC 61472 Ed. 2.0 b:2004 PDF

Published Date:
07/15/2004

Status:
[ Withdrawn ]

Description:

Live working - Minimum approach distances for a.c. systems in the voltage range 72,5 kV to 800 kV - A method of calculation

Publisher:
International Electrotechnical Commission

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$77.1
Need Help?
Describes a method for calculating the minimum approach distances for live working, at maximum voltages between 72,5 kV and 800 kV. This standard addresses system overvoltages, and the working air distances between parts and/or workers at different potentials. The required withstand voltage and minimum approach distances calculated by the method described in this standard are evaluated taking into consideration the following: - workers are trained for, and skilled in, working in the live working zone; - the anticipated overvoltages do not exceed the value selected for the determination of the required minimum approach distance; - transient overvoltages are the determining overvoltages; - tool insulation has no continuous film of moisture present on the surface; - no lightning is seen or heard within 10 km of the work site; - allowance is made for the effect of conducting components of tools; - the effect of altitude on the electric strength is taken into consideration. For conditions other than the above, the evaluation of the minimum approach distances may require specific data, derived by other calculation or obtained from additional laboratory investigations on the actual situation.
Edition : 2.0
File Size : 1 file , 1000 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 85
Published : 07/15/2004

History

IEC 61472 Ed. 3.0 b:2013
Published Date: 04/11/2013
Live working - Minimum approach distances for a.c. systems in the voltage range 72,5 kV to 800 kV - A method of calculation
$98.7
IEC 61472 Ed. 2.0 b:2004
Published Date: 07/15/2004
Live working - Minimum approach distances for a.c. systems in the voltage range 72,5 kV to 800 kV - A method of calculation
$77.1

Related products

IEC 61032 Ed. 2.0 b:1997
Published Date: 12/22/1997
Protection of persons and equipment by enclosures - Probes for verification
$70.2
IEC 60050-651 Ed. 2.0 b:2014
Published Date: 04/04/2014
International Electrotechnical Vocabulary (IEV) - Part 651: Live working
$98.7
IEC 60364-5-52 Ed. 3.0 b:2009
Published Date: 10/20/2009
Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems
$125.1

Best-Selling Products

VITA 1.1
Published Date: 01/01/1997
VME64 Extensions
VITA 1.3
Published Date: 01/01/1997
VME64x 9U x 400 mm Format
VITA 1.5
Published Date: 01/01/2003
2eSST Source Synchronous Transfer
VITA 1.6
Published Date: 01/01/2000
Keying for Conduction Cooled VME64x
VITA 1.7
Published Date: 01/01/2003
Increased Current DIN Connector
VITA 12
Published Date: 01/01/1997
M-Module