IEC 61810-2-1:2017 specifies reliability test procedures for electromechanical elementary relays when enhanced requirements for the verification of reliability apply.
Particular provisions are given for relays incorporated in safety-related control systems of machinery in accordance with IEC 62061 and ISO 13849-1. For such relays,
B10 values for dangerous failures (
B10D values) are derived from the tests specified in this document.
This edition includes the following significant technical changes with respect to the previous edition:
- limitation of tests to 10 M cycles in Clause 5;
- reduction of required number of test samples to 5 in specified cases;
- introduction of WeiBayes analysis for routine test under Clause 4.
| Edition : | 2.0 |
| File Size : | 1
file
, 510 KB |
| Note : | This product is unavailable in Ukraine, Russia, Belarus |
| Number of Pages : | 33 |
| Published : | 05/30/2017 |