IEC 62439-5 Ed. 1.0 en:2010 PDF

IEC 62439-5 Ed. 1.0 en:2010 PDF

Name:
IEC 62439-5 Ed. 1.0 en:2010 PDF

Published Date:
02/26/2010

Status:
Active

Description:

Industrial communication networks - High availability automation networks - Part 5: Beacon Redundancy Protocol (BRP)

Publisher:
International Electrotechnical Commission

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$64.2
Need Help?
IEC 62439-5:2010(E) is applicable to high-availability automation networks based on the ISO/IEC 8802-3 (IEEE 802.3) (Ethernet) technology. It specifies a redundancy protocol that is based on the duplication of the network, the redundancy protocol being executed within the end nodes, as opposed to a redundancy protocol built in the switches. Fast error detection is provided by two beacon nodes, the switchover decision is taken in every node individually. The cross-network connection capability enables single attached end nodes to be connected on either of the two networks. It cancels and replaces IEC 62439 published in 2008 and constitutes a technical revision. It includes the following significant technical changes with respect to IEC 62439 (2008):
- adding a calculation method for RSTP (rapid spanning tree protocol, IEEE 802.1Q),
- adding two new redundancy protocols: HSR (High-availability Seamless Redundancy) and DRP (Distributed Redundancy Protocol),
- moving former Clauses 1 to 4 (introduction, definitions, general aspects) and the Annexes (taxonomy, availability calculation) to IEC 62439-1, which serves now as a base for the other documents,
- moving Clause 5 (MRP) to IEC 62439-2 with minor editorial changes,
- moving Clause 6 (PRP) was to IEC 62439-3 with minor editorial changes,
- moving Clause 7 (CRP) was to IEC 62439-4 with minor editorial changes, and
- moving Clause 8 (BRP) was to IEC 62439-5 with minor editorial changes,
- adding a method to calculate the maximum recovery time of RSTP in a restricted configuration (ring) to IEC 62439-1 as Clause 8,
- adding specifications of the HSR (High-availability Seamless Redundancy) protocol, which shares the principles of PRP to IEC 62439-3 as Clause 5, and
- introducing the DRP protocol as IEC 62439-6.

This publication is to be read in conjunction with IEC 62439-1:2010.
Edition : 1.0
File Size : 1 file , 1 MB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 41
Published : 02/26/2010

History

IEC 62439-5 Ed. 1.0 b:2010
Published Date: 02/26/2010
Industrial communication networks - High availability automation networks - Part 5: Beacon Redundancy Protocol (BRP)
$83.4
IEC 62439-5 Ed. 1.0 en:2010
Published Date: 02/26/2010
Industrial communication networks - High availability automation networks - Part 5: Beacon Redundancy Protocol (BRP)
$64.2

Related products

IEC 61508-1 Ed. 2.0 b:2010
Published Date: 04/30/2010
Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see
$125.1
IEC 61158-3 Ed. 3.0 en:2003
Published Date: 05/27/2003
Digital data communications for measurement and control - Fieldbus for use in industrial control systems - Part 3: Data link service definition
$77.4
IEC 61691-1-1 Ed. 3.0 en:2023
Published Date: 10/01/2023
Behavioural languages – Part 1-1: VHDL Language Reference Manual
$153.6
IEC 61691-5 Ed. 1.0 en:2004
Published Date: 10/07/2004
Behavioural languages - Part 5: VITAL ASIC (application specific integrated circuit) modeling specification
$94.8

Best-Selling Products