IEEE 1528-2013 PDF

IEEE 1528-2013 PDF

Name:
IEEE 1528-2013 PDF

Published Date:
09/06/2013

Status:
Active

Description:

IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques

Publisher:
IEEE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$75.9
Need Help?
Revision Standard - Superseded. Protocols and test procedures are specified for the measurement of the peak spatial-average SAR induced inside a simplified model of the head of users of certain handheld radio transceivers. These transceivers are intended to be used for personal wireless communications services, operate in the 300 MHz to 6 GHz frequency range, and are intended to be operated while held against the ear. The results obtained by following the protocols specified in this recommended practice represent a conservative estimate of the peak spatial-average SAR induced in the head of a significant majority of persons, subject to measurement and other uncertainties that are defined in this recommended practice. The results are representative of those expected during conditions of intended use of a handheld wireless device. It is not the intent of this recommended practice to provide a result representative of the absolute maximum SAR value possible under every conceivable combination of head size, head shape, handset orientation, and spacing relative to the head. The measurement of SAR induced in the external tissues of the head, e.g., the external ear (pinna), is not addressed in this document. This recommended practice also does not address the body SAR measurements typically required for wireless handsets. The following items are described in detail: measurement concepts, measurement techniques, instruments, calibration techniques, simulated-tissue (phantom) models, including homogeneous anatomically equivalent models of the human head and simple phantoms for validation of the SAR measurement system, and the limitations of these systems when used for measuring the spatial-peak mass-averaged SAR. Procedures for calibrating electric field (E-field) probes used for SAR measurements and assessing the SAR measurement and system uncertainties are provided in the annexes. This recommended practice is intended primarily for use by engineers and other specialists who are familiar with electromagnetic (EM) theory and SAR measurement techniques; it does not recommend specific SAR limit values since these are found in other documents. The benefits to the users include standardized and accepted protocols, validation techniques, and means for estimating the overall measurement uncertainty in order to produce valid and repeatable data.
File Size : 1 file , 4.5 MB
ISBN(s) : 9780738189154, 9780738185262
Number of Pages : 246
Product Code(s) : STDRL98305, STDSURL98305, STDSU98305
Published : 09/06/2013
Redline File Size : 2 files , 10 MB

History

IEEE 1528-2013
Published Date: 09/06/2013
IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques
$75.9
IEEE 1528-2003
Published Date: 12/19/2003
IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques
$37.8

Related products

IEEE C95.3-2021
Published Date: 05/30/2021
IEEE Recommended Practice for Measurements and Computations of Electric, Magnetic, and Electromagnetic Fields with Respect to Human Exposure to Such Fields, 0 Hz to 300 GHz
IEEE 1309-2013
Published Date: 11/22/2013
IEEE Standard for Calibration of Electromagnetic Field Sensors and Probes (Excluding Antennas) from 9 kHz to 40 GHz
$57.3
IEEE C95.1-2019
Published Date: 10/04/2019
IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz
$111

Best-Selling Products

JIS A 0005:1966
Published Date: 01/01/1966
Standard nominal size of opening components for buildings
$25.5
JIS A 0007:1967
Published Date: 01/01/1967
Standard nominal size of steel framed wall component for buildings
$14.1
JIS A 0008:1967
Published Date: 01/01/1967
Standard nominal size of steel framed roof component for buildings
$11.7
JIS A 0012:1980
Published Date: 01/01/1980
Modular co-ordination -- Sizes of sanitary unit for dwellings
$15.3
JIS A 0015:1976
Published Date: 01/01/1976
Modular co-ordinating sizes of piping unit for dwellings
$12.9
JIS A 0016:1979
Published Date: 01/01/1979
Modular coordination-coordinating size of opening for built-in appliances in storage furniture
$19.2