IEEE C57.12.34-2009 PDF

IEEE C57.12.34-2009 PDF

Name:
IEEE C57.12.34-2009 PDF

Published Date:
03/11/2010

Status:
Active

Description:

IEEE Standard Requirements for Pad-Mounted, Compartmental-Type, Self-Cooled, Three-Phase Distribution Transformers, 5 MVA and Smaller; High Voltage, 34.5 kV Nominal System Voltage and Below; Low Voltage, 15 kV Nominal System Voltage & Below

Publisher:
IEEE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$28.2
Need Help?
Revision Standard - Superseded. Certain electrical, dimensional, and mechanical characteristics are set forth as well as certain safety features of three-phase, 60 Hz, mineral-oil-immersed, self-cooled, pad-mounted, compartmental-type distribution transformers. These transformers are rated 5 MVA and smaller, with the high-voltage limit of 34.5 kV system nominal voltage and below, and with low-voltage limit of 15 kV system nominal voltage and below. This standard covers the connector, bushing, and terminal arrangements for radial- or loop-feed systems. This standard does not cover the electrical and mechanical requirements of any accessory devices that may be supplied with the transformer.
File Size : 1 file , 500 KB
ISBN(s) : 9780738161747, 9780738161730
Note : This product is unavailable in Russia, Belarus
Number of Pages : 41
Product Code(s) : STDSU96022
Published : 03/11/2010

History

IEEE C57.12.34-2022
Published Date: 12/21/2022
IEEE Standard Requirements for Pad-Mounted, Compartmental-Type, Self-Cooled, Three-Phase Distribution Transformers, 10 MVA and Smaller; High-Voltage, 34.5 kV Nominal System Voltage and Below; Low-Voltage, 15 kV Nominal System Voltage and Below
$23.4
IEEE C57.12.34-2009
Published Date: 03/11/2010
IEEE Standard Requirements for Pad-Mounted, Compartmental-Type, Self-Cooled, Three-Phase Distribution Transformers, 5 MVA and Smaller; High Voltage, 34.5 kV Nominal System Voltage and Below; Low Voltage, 15 kV Nominal System Voltage & Below
$28.2
IEEE C57.12.34-2004
Published Date: 03/08/2005
Standard for Requirements for Pad-Mounted, Compartmental-Type, Self-Cooled, Three-Phase DistributionTransformers, 2500 kVA and Smaller: High-Voltage, 34 500GrdY/19 920 Volts and Below; Low Voltage, 480 Volts and Below
$26.1

Related products

IEEE C57.12.29-2023
Published Date: 05/03/2024
IEEE Standard for Pad-Mounted Equipment--Enclosure Integrity for Coastal Environments
$19.2
IEEE C57.12.28-2023
Published Date: 05/03/2024
IEEE Standard for Pad-Mounted Equipment--Enclosure Integrity
$18.6
IEEE C57.12.00-2021
Published Date: 01/21/2022
IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
$27.9

Best-Selling Products

ANS 1-1967
Published Date: 08/18/1967
A Code of Good Practices for the Performance of Critical Experiments
$5.7
ANS 1-1972
Published Date: 08/19/1971
Safety Guide for the Performance of Critical Experiments
$15
ANS 1-1975 (R1981)
Published Date: 04/29/1975
Safety Guide for the Performance of Critical Experiments
$15
ANS 1-1987(R1992)
Published Date: 06/24/1987
Safety Guide for the Performance of Critical Experiments
$16.5
ANS 1-2000 (R2024)
Published Date: 03/23/2000
Conduct of Critical Experiments
$16.5
ANS 10.2-1971 (ANS.STD. 3)
Published Date: 04/01/1971
Recommended Programming Practices to Facilitate the Interchange of Digital Computer Programs
$11.7