ISO/TR 3313:1998 PDF

ISO/TR 3313:1998 PDF

Name:
ISO/TR 3313:1998 PDF

Published Date:
08/01/1998

Status:
[ Withdrawn ]

Description:

Measurement of fluid flow in closed conduits - Guidelines on the effects of flow pulsations on flow-measurement instruments

Publisher:
International Organization for Standardization (Technical Report)

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$49.2
Need Help?

This Technical Report defines pulsating flow, compares it with steady flow, indicates how it can be detected, and describes the effects it has on orifice plates, nozzles or Venturi tubes, turbine and vortex flowmeters when these devices are being used to measure fluid flow in a pipe. These particular flowmeter types feature in this Technical Report because they are amongst those types most susceptible to pulsation effects. Methods for correcting the flowmeter output signal for errors produced by these effects are described for those flowmeter types for which this is possible. When correction is not possible, measures to avoid or reduce the problem are indicated. Such measures include the installation of pulsation damping devices and/or choice of a flowmeter type which is less susceptible to pulsation effects.

This Technical Report applies to flow in which the pulsations are generated at a single source which is situated either upstream or downstream of the primary element of the flowmeter. Its applicability is restricted to conditions where the flow direction does not reverse in the measuring section but there is no restriction on the waveform of the flow pulsation. The recommendations within this Technical Report apply to both liquid and gas flows although with the latter the validity may be restricted to gas flows in which the density changes in the measuring section are small as indicated for the particular type of flowmeter under discussion.


File Size : 1 file , 200 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 40
Published : 08/01/1998
Same As : ISO/TR 3313:1998

History

ISO/TR 3313:2018
Published Date: 03/01/2018
Measurement of fluid flow in closed conduits - Guidelines on the effects of flow pulsations on flow-measurement instruments
$66.9
ISO/TR 3313:1998
Published Date: 08/01/1998
Measurement of fluid flow in closed conduits - Guidelines on the effects of flow pulsations on flow-measurement instruments
$49.2

Related products


Best-Selling Products

ISO/ASTM 51026:2015
Published Date: 07/15/2015
Practice for using the Fricke dosimetry system
$24.3
ISO/ASTM 51204:2004
Published Date: 08/01/2004
Practice for dosimetry in gamma irradiation facilities for food processing
$10.5
ISO/ASTM 51205:2009
Published Date: 01/01/2009
Practice for use of a ceric-cerous sulfate dosimetry system
ISO/ASTM 51205:2017
Published Date: 07/15/2015
Practice for use of a ceric-cerous sulfate dosimetry system
$20.4
ISO/ASTM 51261:2002
Published Date: 03/01/2002
Guide for selection and calibration of dosimetry systems for radiation processing
$12.3
ISO/ASTM 51261:2013
Published Date: 04/15/2013
Practice for calibration of routine dosimetry systems for radiation processing
$37.2