ISO/PAS 21448:2019 PDF

ISO/PAS 21448:2019 PDF

Name:
ISO/PAS 21448:2019 PDF

Published Date:
01/31/2019

Status:
[ Withdrawn ]

Description:

Road vehicles - Safety of the intended functionality

Publisher:
International Organization for Standardization / PAS

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
iso-pas-21448-2019_2035283

Choose Document Language:
67.50 €
Need Help?

The absence of unreasonable risk due to hazards resulting from functional insufficiencies of the intended functionality or by reasonably foreseeable misuse by persons is referred to as the Safety Of The Intended Functionality (SOTIF). This document provides guidance on the applicable design, verification and validation measures needed to achieve the SOTIF. This document does not apply to faults covered by the ISO 26262 series or to hazards directly caused by the system technology (e.g. eye damage from a laser sensor).

This document is intended to be applied to intended functionality where proper situational awareness is critical to safety, and where that situational awareness is derived from complex sensors and processing algorithms; especially emergency intervention systems (e.g. emergency braking systems) and Advanced Driver Assistance Systems (ADAS) with levels 1 and 2 on the OICA/SAE standard J3016 automation scales. This edition of the document can be considered for higher levels of automation, however additional measures might be necessary. This document is not intended for functions of existing systems for which well-established and well-trusted design, verification and validation (V&V) measures exist at the time of publication (e.g. Dynamic Stability Control (DSC) systems, airbag, etc.). Some measures described in this document are applicable to innovative functions of such systems, if situational awareness derived from complex sensors and processing algorithms is part of the innovation.

Intended use and reasonably foreseeable misuse are considered in combination with potentially hazardous system behaviour when identifying hazardous events.

Reasonably foreseeable misuse, which could lead directly to potentially hazardous system behaviour, is also considered as a possible event that could directly trigger a SOTIF-related hazardous event.

Intentional alteration to the system operation is considered feature abuse. Feature abuse is not in scope of this document.


Edition : 1st
File Size : 1 file , 7.3 MB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 64
Published : 01/31/2019
Same As : ISO/PAS 21448:2019

History

ISO/PAS 21448:2019
Published Date: 01/31/2019
Road vehicles - Safety of the intended functionality
67.50 €

Related products


Best-Selling Products

IES 500-97
Published Date: 01/01/1997
NECA/IESNA Recommended Practice for Installing Indoor Commercial Lighting Systems
IES 90.1-2007 (IP)
Published Date: 02/01/2008
Energy Standard for Building Except Low-Rise Residential Buildings, IP Edition
IES AEDG-1-05
Published Date: 01/01/2005
Advanced Energy Design Guide For Small Office Buildings
IES DG-10-98
Published Date: 01/01/1998
Choosing Light Sources for General Lighting
IES DG-16-05
Published Date: 01/01/2005
Guidelines for Professional Filming or Photographing Works of Art in Museums
IES DG-18-08
Published Date: 11/09/2008
Light + Design: A Guide to Designing Quality Lighting for People and Buildings