ISA 12.12.01 PDF

ISA 12.12.01 PDF

Name:
ISA 12.12.01 PDF

Published Date:
07/09/2012

Status:
[ Revised ]

Description:

Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified) Locations

Publisher:
The International Society of Automation

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$11.1
Need Help?

This standard applies only to equipment, circuits, and components designed specifically for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) locations as defined in the National Electrical Code® (NEC®) ANSI/NFPA 70. NOTE Some equipment designed for use in unclassified locations is permitted by the NEC®for installing in Division 2 locations. The judgment of acceptability for the installation would b e determined by the authority having jurisdiction. Such equipment would not have the hazardous location marking or documentation described in this standard. It is anticipated that such equipment would comply with the other requirements in this standard and that the determination of compliance is elementary (e.g., a nonarcing instrument inside a NEMA Type 4 or 12 enclosure used in a Class II, Division 2 location).

This standard also applies to certain unclassified location equipment specifically designed to directly connect to nonincendive field wiring in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) locations as defined in the NEC®.

This standard is primarily intended to provide requirements for electrical and electroni c test, measuring, and controlling equipment.

This standard is concerned only with equipment construction and test criteria related to electrical or thermal ignition of specified flammable gases, vapors, combustible dusts, fibers, and flyings in air.

This standard is not intended to cover equipment for use in Class I and Class II, Division 1 locations, such as equipment constructed to be intrinsically safe, dust ignition-proof, or explosion-proof. Such equipment is, however, suitable for use in Class I and Class II, Division 2 locations in the same group and temperature class for which it is suitable in Division 1.

This standard does not cover mechanisms of ignition from external sources, such as static electricity or lightning, that are not related to the electrical characteristics of the equipment.

This standard is not intended as an instructional manual for untrained persons. It is intended to promote uniformity of practice among those skilled in the area of design, construction, and application of equipment suitable for Class I and Class II, Division 2 and Class III, Divisions 1 and 2 locations.

The requirements of this standard are based on consideration of ignition in locations made hazardous by the presence of flammable gases, vapors, combustible dusts, fibers, and flyings under the following ambient conditions:

a) an ambient temperature of -25°C to 40°C

b) an oxygen concentration of not greater than 21 percent by volume

c) a pressure of 80 kPa (0.8 bar) to 110 kPa (1.1 bar)

NOTE If equipment is specified to operate in conditions outside the ranges listed above, the requirements of this standard may not ensure the desired level of safety.

This standard covers portable battery-powered equipment other than flashlights and lanterns for Class I and Class II, Division 2, and Class III, Divisions 1 and 2 hazardous (classified) locations.

This standard does not cover electric luminaires for use in Division 2 hazardous (classified) locations.

This standard does not cover electric motors, electric heaters, heat tracing c ables, and similar heat-producing devices, except where they are an integral part of the equipment under evaluation, for use in Division 2 locations.

This standard does not cover AEx requirements for equipment for use in Class I, Zone 2 hazardous (classified) locations.

This standard does not cover the requirements for equipment for use in Zone 20, Zone 21 or Zone 22.

Purpose

The purpose of this standard is to provide minimum requirements for the design, construction, and marking of electrical equipment or parts of such equipment for use in Class I and Class II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) locations. This equipment, in normal operation, is not capable of causing ignition of the surrounding atmosphere under the conditions prescribed in this standard, although the equipment may contain electronic components that operate at incendive levels and may also have field wiring that is incendive. In addition, it is the intent of this document to establish uniformity in test methods for determining the suitability of the equipment and associated circuits and components as they relate to potential ignition of a specific flammable gas or vapour-in-air mixture, combustible dust, easily ignitible fibers, or flyings.


ANSI : ANSI Approved
Edition : 12
File Size : 1 file , 790 KB
Number of Pages : 46
Published : 07/09/2012

History

ISA 12.12.01
Published Date: 11/17/2015
Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified) Locations
$39.3
ISA 12.12.01
Published Date: 08/21/2015
Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified) Locations
$12.9
ISA 12.12.01
Published Date: 06/03/2013
Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified) Locations
$11.7
ISA 12.12.01
Published Date: 07/09/2012
Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified) Locations
$11.1
ISA 12.12.01
Published Date: 01/01/2011
Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified) Locations
$11.1
ISA 12.12.01
Published Date: 01/01/2010
Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified) Locations
$11.1
ISA 12.12.01
Published Date: 04/12/2007
Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified) Locations
$11.1
ISA 12.12.01
Published Date: 01/01/2000
Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified) Locations
$11.7

Related products

ISA 12.02.04
Published Date: 01/01/2006
Fieldbus Intrinsically Safe Concept (FISCO) and Fieldbus Non-Incendive Concept (FNICO)
$6.9
ISA 95.00.01
Published Date: 05/13/2010
Enterprise-Control System Integration − Part 1: Models and Terminology
$203.7

Best-Selling Products

ASSE (Plumbing) 1001-2008
Published Date: 02/18/2008
Performance Requirements for Atmospheric Type Vacuum Breakers
$13.5
ASSE (Plumbing) 1001-2017
Published Date: 06/01/2017
Performance Requirements for Atmospheric Type Vacuum Breakers
$13.5
ASSE (Plumbing) 1001-2021
Published Date: 11/01/2021
Performance Requirements for Atmospheric Type Vacuum Breakers
$13.5
ASSE (Plumbing) 1002-2008
Published Date: 04/28/2008
Performance Requirements for Anti-Siphon Fill Valves for Water Closet Tanks
$13.5
ASSE (Plumbing) 1002-2020/ASME A112.1002-2020/CSA B125.12:20
Published Date: 04/01/2020
Anti-Siphon Fill Valves for Water Closet Tanks
$25.5
ASSE (Plumbing) 1003-2009
Published Date: 09/28/2009
Performance Requirements for Water Pressure Reducing Valves for Domestic Water Distribution Systems
$13.5