Electrical Apparatus for Use in Class I, Zone 2 Hazardous (Classified) Locations: Type of Protection "n"

Publisher:
The International Society of Automation

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$23.1
Need Help?

This standard specifies requirements for the construction, testing and marking for Group II electrical apparatus with type of protection, "n" intended for use in Class I, Zone 2 hazardous (classified) locations as defined by the National Electrical Code® (NEC®), ANSI/NFPA 70.

This standard is applicable to non-sparking electrical apparatus and also to electrical apparatus with parts or circuits producing arcs or sparks or having hot surfaces which, if not protected in one of the ways specified in this standard, could be capable of igniting a surrounding explosive gas atmosphere. This standard describes several different methods by which this can be achieved which may be combined with other methods described in ANSI/ISA-60079-0.

This standard supplements the general requirements in ANSI/ISA-60079-0.

NOTE 1 A non-incendive component is limited in use to the particular circuit for which it has been shown to be nonignition capable and, therefore, cannot be separately assessed as complying with this standard.

NOTE 2 Compliance with this standard does not imply any removal of, or lowering of the requirements of any other standard with which the electrical apparatus complies.

NOTE 3 This part supplements, and may enhance, the requirements for apparatus for normal industrial applications. Where compliance with other IEC standards is indicated, such as IEC 60034 for motors and IEC 60598-2 for luminaires, proving compliance to those standards is normally the responsibility of the manufacturer.

NOTE 4 The National Electrical Code® (NFPA 70®) through the 2008 edition only recognizes types of protection "nA", "nC" and "nR" and not "nL". See note in 35.1.


ANSI : ANSI Approved
Edition : 09
File Size : 1 file , 570 KB
Number of Pages : 100
Published : 07/17/2009

History

ISA 60079-15
Published Date: 01/01/2012
Explosive atmospheres – Part 15: Equipment protection by type of protection "n"
$182.7
ISA 60079-15
Published Date: 07/17/2009
Electrical Apparatus for Use in Class I, Zone 2 Hazardous (Classified) Locations: Type of Protection "n"
$23.1
ISA 60079-15
Published Date: 05/05/2003
Electrical Apparatus for Use in Class I, Zone 2 Hazardous (Classified) Locations - Type of Protection "n"
$14.4

Related products

ISA 75.16
Published Date: 08/24/1994
Face-to-Face Dimensions for Flanged Globe-Style Control Valve Bodies (ANSI Classes 900, 1500, and 2500)
$6.6
ISA 67.14.01
Published Date: 02/15/2000
Qualifications and Certification of Instrumentation and Control Technicians in Nuclear Facilities
$21.9
ISA 60079-10-1
Published Date: 08/15/2014
Explosive Atmospheres – Part 10-1: Classification of areas – Explosive gas atmospheres
$173.7

Best-Selling Products

AEIC CG1-19
Published Date: 06/01/2019
Guide for Establishing the Maximum Operating Temperatures of Impregnated Paper and Laminated Paper Polypropylene Insulated Cable - 5th Edition
$15
AEIC CG14-19
Published Date: 10/24/2019
Guide for the Design of Transmission Vaults - 1st Edition
$21
AEIC CG3-21
Published Date: 02/01/2022
Guide for Installation of Pipe-Type Cable Systems - 3rd Edition
$15
AEIC CG4-97
Published Date: 01/01/1997
Guide for Installation of Extruded Dielectric Insulated Power Cable Systems Rated 69 kV Through 138 kV - 2nd Edition
$15
AEIC CG5-05
Published Date: 06/01/2005
Underground Extruded Power Cable Pulling Guide
AEIC CS2-23
Published Date: 02/01/2023
Specification for Impregnated Paper and Laminated Paper Polypropylene Insulated High Pressure Pipe Type Cable - 8th Edition
$36