Electrical Apparatus for Use in Zone 21 and Zone 22 Hazardous (Classified) Locations − Protection by Pressurization “pD”

Publisher:
The International Society of Automation

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
isa-61241-2_2862732

Choose Document Language:
56.70 €
Need Help?
12.10.06

This standard gives requirements on the design, construction, testing and marking of electrical apparatus for use in combustible dust atmospheres in which a protective gas (air or inert gas), maintained at a pressure above that of the external atmosphere, is used to prevent the entry of dust which might otherwise lead to the formation of a combustible mixture within enclosures which do not contain a source of combustible dust.

This standard contains the specific requirements for construction and testing, including protective requirements that apply to electrical apparatus with type of protection pressurization "pD" intended for use in potentially combustible dust atmospheres.

This standard includes the requirements for the construction of the enclosure and its associated components, including, if any, the inlet and outlet ducts for the protective gas, and for the safety provisions and devices necessary to ensure that pressurization is established and maintained for type of protection pressurization "pD".

Requirements for pressurized enclosures with an internal source of dust release are not included in this standard.

This standard does not cover the requirements for pressurized rooms with or without internal sources of dust release.

This standard does not apply to dusts of explosives which do not require atmospheric oxygen for combustion or to pyrophoric substances.

This standard does not cover combined gas and dust hazard. Those requirements are under consideration.

The requirements contained in this standard are supplementary to those in ANSI/ISA-61241-0.


ANSI : ANSI Approved
Edition : 06
File Size : 1 file , 570 KB
Number of Pages : 38
Published : 01/01/2006

History

ISA 61241-2
Published Date: 01/01/2006
Electrical Apparatus for Use in Zone 21 and Zone 22 Hazardous (Classified) Locations − Protection by Pressurization “pD”
56.70 €
ISA 61241-2
Published Date: 01/01/2006
Electrical Apparatus for Use in Zone 21 and Zone 22 Hazardous (Classified) Locations − Protection by Pressurization “pD”
9.60 €
ISA 61241-2
Published Date: 01/01/2006
Electrical Apparatus for Use in Zone 21 and Zone 22 Hazardous (Classified) Locations – Protection by Pressurization “pD”
9.00 €

Related products

ISA 12.20.01
Published Date: 05/04/2009
General Requirements for Electrical Ignition Systems for Internal Combustion Engines in Class I, Division 2 or Zone 2, Hazardous (Classified) Locations
34.80 €
ISA 75.08.02
Published Date: 01/01/2003
Face-to-Face Dimensions for Flanged and Flangeless Rotary Control Valves (Classes 150, 300, and 600, and PN 10, PN 16, PN 25, PN 40, PN 63 and PN 100)
17.40 €
ISA 75.15
Published Date: 01/01/1994
Face-to-Face Dimensions for Buttweld-End Globe-Style Control Valves (ANSI Classes 150, 300, 600, 900, 1500, and 2500)
6.60 €

Best-Selling Products

PCI 126-15
Published Date: 2015
Manual for the Design of Hollow Core Slabs and Walls
PCI 128-19
Published Date: 2019
Specification for Glass-Fiber-Reinforced Concrete Panels
39.60 €
PCI 142-24
Published Date: 2024
Specification for Precast, Prestressed Concrete Piles
39.60 €
PCI 150-24
Published Date: 2024
Specification for the Design of Precast Concrete Insulated Wall Panels
39.60 €
PCI BM-20
Published Date: 2004
Precast Prestressed Concrete Piles - Chapter 20, Bridge Design Manual, Sept. 2004, 1st Edition
3.30 €
PCI CB-02-16
Published Date: 2016
Recommended Practice for Lateral Stability of Precast, Prestressed Concrete Bridge Girders
36.30 €