ISA 61241-2 PDF

ISA 61241-2 PDF

Name:
ISA 61241-2 PDF

Published Date:
01/01/2006

Status:
[ Active ]

Description:

Electrical Apparatus for Use in Zone 21 and Zone 22 Hazardous (Classified) Locations − Protection by Pressurization “pD”

Publisher:
The International Society of Automation

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$56.7
Need Help?
12.10.06

This standard gives requirements on the design, construction, testing and marking of electrical apparatus for use in combustible dust atmospheres in which a protective gas (air or inert gas), maintained at a pressure above that of the external atmosphere, is used to prevent the entry of dust which might otherwise lead to the formation of a combustible mixture within enclosures which do not contain a source of combustible dust.

This standard contains the specific requirements for construction and testing, including protective requirements that apply to electrical apparatus with type of protection pressurization "pD" intended for use in potentially combustible dust atmospheres.

This standard includes the requirements for the construction of the enclosure and its associated components, including, if any, the inlet and outlet ducts for the protective gas, and for the safety provisions and devices necessary to ensure that pressurization is established and maintained for type of protection pressurization "pD".

Requirements for pressurized enclosures with an internal source of dust release are not included in this standard.

This standard does not cover the requirements for pressurized rooms with or without internal sources of dust release.

This standard does not apply to dusts of explosives which do not require atmospheric oxygen for combustion or to pyrophoric substances.

This standard does not cover combined gas and dust hazard. Those requirements are under consideration.

The requirements contained in this standard are supplementary to those in ANSI/ISA-61241-0.


ANSI : ANSI Approved
Edition : 06
File Size : 1 file , 570 KB
Number of Pages : 38
Published : 01/01/2006

History

ISA 61241-2
Published Date: 01/01/2006
Electrical Apparatus for Use in Zone 21 and Zone 22 Hazardous (Classified) Locations − Protection by Pressurization “pD”
$56.7
ISA 61241-2
Published Date: 01/01/2006
Electrical Apparatus for Use in Zone 21 and Zone 22 Hazardous (Classified) Locations − Protection by Pressurization “pD”
$9.6
ISA 61241-2
Published Date: 01/01/2006
Electrical Apparatus for Use in Zone 21 and Zone 22 Hazardous (Classified) Locations – Protection by Pressurization “pD”
$9

Related products

ISA 12.20.01
Published Date: 05/04/2009
General Requirements for Electrical Ignition Systems for Internal Combustion Engines in Class I, Division 2 or Zone 2, Hazardous (Classified) Locations
$34.8
ISA 75.08.02
Published Date: 01/01/2003
Face-to-Face Dimensions for Flanged and Flangeless Rotary Control Valves (Classes 150, 300, and 600, and PN 10, PN 16, PN 25, PN 40, PN 63 and PN 100)
$17.4
ISA 75.15
Published Date: 01/01/1994
Face-to-Face Dimensions for Buttweld-End Globe-Style Control Valves (ANSI Classes 150, 300, 600, 900, 1500, and 2500)
$6.6

Best-Selling Products

IDEMA H7-94
Published Date: 01/01/1994
Sign Convention Standard
IDEMA H8-94
Published Date: 01/01/1994
Glossary of Suspension Terms Purpose
IDEMA R1-98
Published Date: 01/01/1998
HDD Handling Environment Assessment & Simulation Test Procedure using Test Tailoring
$13.8
IDEMA T11-91
Published Date: 01/01/1991
Window Margin