ISA TR77.60.04 PDF

ISA TR77.60.04 PDF

Name:
ISA TR77.60.04 PDF

Published Date:
05/24/1996

Status:
[ Revised ]

Description:

Fossil Fuel Power Plant Human-Machine Interface - Human-Machine Interface — Electronic Screen Displays

Publisher:
The International Society of Automation

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.8
Need Help?

This technical report is provided for the benefit of design engineers and ultimately fossil-power plant operators. By following this technical report, the developer of Electronic Screen Displays will

a) provide clear and efficient communication between the user and the distributed control system, SCADA and/or PLC based system with HMI;

b) accomplish display design based on the user's needs that are based on an assessment of planned control-operator functions to be performed; and

c) provide a display design to obtain timely access to required information and controls in a logical structure convenient to the user.

The display structure and organization, including access time to make appropriate control adjustments, should provide for operator response comparable to that of non-display-based, human-machine interface systems. To meet this requirement, the display structure must be developed using

a) clearly designed display accessing techniques;

b) a set of well-structured display relationships, predictable and familiar to the user;

c) standard display formats to increase speed of access to items within a display;

d) logical grouping of functions and tasks that minimize memorization of elements or results from previous displays;

e) separation of overview graphics to simplify control graphics, preventing a "cluttering" of information and facilitating quicker display updates;

f) as few levels as possible going from the overview display to the detail displays; and

g) consistent use of colors, patterns, symbols, shapes, etc. throughout the entire set of graphics.

Input from plant operating personnel in all phases of Electronic Screen Display development is critical to the development of effective displays. It is even recommended to have plant operating personnel build many of the graphics to ensure a sense of ownership by operations personnel.

This technical report will address the following issues relating to Electronic Screen Display development: Display structure Display elements Display access Operator entry techniques Display types Control applications Format standards Alarm management Display organization Work station ergonomics Coding conventions

Recognizing the substantial volumes of technical reports on the topic of Electronic Screen Display development, the intent of this report is to provide a summary/overview of the important considerations that apply in the development of effective Electronic Screen Displays. For additional detailed guidance, please refer to Annex A — References

Purpose

The purpose of this technical report is to provide advice and guidance in the development of Electronic Screen Displays for use in conjunction with real-time Distributed Control Systems (DCS) used in utility fossil-fired power plants with boilers of 200,000 lb/hr or greater capacity.

NOTE - Distributed Control Systems are also referred to as Digital Control Systems


Edition : 96
File Size : 1 file , 92 KB
Number of Pages : 30
Published : 05/24/1996

History

ISA TR77.60.04
Published Date: 11/26/2013
Fossil Fuel Power Plant Human-Machine Interface - Electronic Screen Displays
$26.1
ISA TR77.60.04
Published Date: 05/24/1996
Fossil Fuel Power Plant Human-Machine Interface - Human-Machine Interface — Electronic Screen Displays
$7.8
ISA TR77.60.04
Published Date: 05/24/1996
Fossil Fuel Power Plant Human-Machine Interface - CRT Displays
$9.6
ISA TR77.60.04
Published Date: 05/24/1996
Fossil Fuel Power Plant Human-Machine Interface - CRT Displays
$8.7

Related products

ISA 75.07
Published Date: 08/31/1997
Laboratory Measurement of Aerodynamic Noise Generated by Control Valves
$17.4
ISA 50.1
Published Date: 01/01/1982
Compatibility of Analog Signals for Electronic Industrial Process Instruments
$12
ISA 75.04
Published Date: 01/01/1995
Face-to-Face Dimensions for Flangeless Control Valves (ANSI Classes 150, 300, and 600)
$6.6
ISA 77.70
Published Date: 01/01/1994
Fossil Fuel Power Plant Instrument Piping Installation
$8.7

Best-Selling Products