This document focuses on monitoring the activity concentrations of radioactive gases. They allow the
calculation of the activity releases, in the gaseous effluent discharge from facilities producing positron
emitting radionuclides and radiopharmaceuticals. Such facilities produce short-lived radionuclides
used for medical purposes or research and can release gases typically including, but not limited to
18F,
11C,
15O and
13N. These facilities include accelerators, radiopharmacies, hospitals and universities. This
document provides performance?based criteria for the design and use of air monitoring equipment
including probes, transport lines, sample monitoring instruments, and gas flow measuring methods.
This document also provides information on monitoring program objectives, quality assurance,
development of air monitoring control action levels, system optimisation and system performance
verification.