Name:
ISO 13736:2021 PDF
Published Date:
04/01/2021
Status:
Active
This document specifies a method for the determination of the manual and automated closed cup flash point of combustible liquids having flash points between °°°30,0°°°°C to 75,0°°°°C. However, the precision given for this method is only valid for flash points in the range °°°8,5°°°°C to 75,0°°°°C.
This document is not applicable to water-borne paints.
NOTE°°1°°°° Water borne paints can be tested using ISO 3679[1].
NOTE°°2°°°° See 9.1 for the importance of this test in avoiding loss of volatile materials.
NOTE°°3°°°° Liquids containing halogenated compounds can give anomalous results.
NOTE°°4°°°° The thermometer specified for the manual apparatus limits the upper test temperature to 70,0°°°°C.
NOTE°°5°°°° See 13.1 for more specific information related to precision.
| File Size : | 1 file , 1.5 MB |
| Note : | This product is unavailable in Ukraine, Russia, Belarus |
| Published : | 04/01/2021 |
| Same As : | ISO 13736:2021 |