Description:

Monitoring radioactive gases in effluents from facilities producing positron emitting radionuclides and radiopharmaceuticals

Publisher:
International Organization for Standardization

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$75
Need Help?

ISO 16640:2021 focuses on monitoring the activity concentrations of radioactive gases. They allow the calculation of the activity releases, in the gaseous effluent discharge from facilities producing positron emitting radionuclides and radiopharmaceuticals. Such facilities produce short-lived radionuclides used for medical purposes or research and can release gases typically including, but not limited to 18F, 11C, 15O and 13N. These facilities include accelerators, radiopharmacies, hospitals and universities. This document provides performance-based criteria for the design and use of air monitoring equipment including probes, transport lines, sample monitoring instruments, and gas flow measuring methods. This document also provides information on monitoring program objectives, quality assurance, development of air monitoring control action levels, system optimisation and system performance verification.

The goal of achieving an unbiased measurement is accomplished either by direct (in-line) measurement on the exhaust stream or with samples extracted from the exhaust stream (bypass), provided that the radioactive gases are well mixed in the airstream. This document sets forth performance criteria and recommendations to assist in obtaining valid measurements.

NOTE 1 The criteria and recommendations of this document are aimed at monitoring which is conducted for regulatory compliance and system control. If existing air monitoring systems were not designed according to the performance criteria and recommendations of this document, an evaluation of the performance of the system is advised. If deficiencies are discovered based on a performance evaluation, a determination of the need for a system retrofit is to be made and corrective actions adopted where practicable.

NOTE 2 The criteria and recommendations of this document apply under both normal and off-normal operating conditions, provided that these conditions do not include production of aerosols or vapours. If the normal and/or off-normal conditions produce aerosols and vapours, then the aerosol collection principles of ISO 2889 also apply.


Edition : 1st
File Size : 1 file , 3 MB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 62
Published : 02/01/2021

History


Related products

ISO 7760:2001
Published Date: 12/15/2001
Photography - Processing waste - Determination of hydroquinone
$24.3
ISO 7766:2003
Published Date: 06/15/2003
Processing photographic wastes - Analysis of cyanides - Determination of hexacyanoferrate (II) and hexacyanoferrate (III) by spectrometry
$24.3
ISO 22444-1:2020
Published Date: 10/01/2020
Rare earth - Vocabulary - Part 1: Minerals, oxides and other compounds
$16.2

Best-Selling Products

TMS 1002-08
Published Date: 01/01/2008
A Transition Guide from the 2005 to the 2008 MSJC
$6
TMS 1222-17
Published Date: 2018
Masonry Basics, 2nd Edition
$10.5
TMS 1409-18
Published Date: 2018
Masonry Structures: Behavior and Design, 4th Edition
$54
TMS 1700-17
Published Date: 2017
Guide for Condition Assessment of Masonry Facades, 2017
$6
TMS 216-07
Published Date: 06/01/2007
Determining Fire Resistance - Concrete and Masonry (ACI 216.1-07 / TMS-0216-07)
$15.6