Surface chemical analysis - Secondary ion mass spectrometry - Correction method for saturated intensity in single ion counting dynamic secondary ion mass spectrometry

Publisher:
International Organization for Standardization

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$37.2
Need Help?

ISO 20411:2018 specifies a method for determining the maximum count rate for an acceptable limit of divergence from linearity of the intensity scale in pulse counting magnetic sector-type secondary ion mass spectrometers or quadrupole secondary ion mass spectrometers. It uses a test based on depth profile analysis of two isotopes in a reference material which has a gradual concentration change between low and high concentration regimes. It also includes a correction method for saturated intensity caused by the dead time of the detector. The correction can increase the intensity range for 95 % linearity so that a higher maximum count rate can be employed for those spectrometers for which the relevant correction equations have been shown to be valid.

ISO 20411:2018 does not apply to time of flight mass spectrometers.

ISO 20411:2018 is only applicable to elements with minor isotopes. It is not applicable if the element is monoisotopic or contains isotopes with equal abundances.


Edition : 1st
File Size : 1 file , 1.3 MB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 22
Published : 03/01/2018
Same As : ISO 20411:2018

History


Related products

ISO 22048:2004
Published Date: 08/15/2004
Surface chemical analysis - Information format for static secondary-ion mass spectrometry
$24.3
ISO 15796:2005
Published Date: 03/01/2005
Gas analysis - Investigation and treatment of analytical bias
$58.2
ISO 16413:2020
Published Date: 08/01/2020
Evaluation of thickness, density and interface width of thin films by X-ray reflectometry - Instrumental requirements, alignment and positioning, data collection, data analysis and reporting
$58.2

Best-Selling Products

UTS AppPack TK5.0 IRF
Published Date:
AppPack TK Solver 5.0 Standard (Standalone) and Interactive Roark's Formulas
UTS INTERACTIVE ROARK
Published Date:
Interactive Roark's Formulas (Standalone)
UTS MATHLOOK
Published Date:
MathLook for Excel (TM)
UTS ROARK FOR EXCEL
Published Date:
Roark’s Formulas for Excel (TM): Control your stress
UTS TK5.0
Published Date:
TK Solver 5.0 Standard (Standalone)