ISO 25539-3:2011 PDF

ISO 25539-3:2011 PDF

Name:
ISO 25539-3:2011 PDF

Published Date:
12/01/2011

Status:
Active

Description:

Cardiovascular implants - Endovascular devices - Part 3: Vena cava filters

Publisher:
International Organization for Standardization

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$83.4
Need Help?

ISO 25539-3:2011 specifies requirements for vena cava filters, based upon current medical knowledge. With regard to safety, it gives requirements for intended performance, design attributes, materials, design evaluation, manufacturing, sterilization, packaging and information supplied by the manufacturer. ISO 25539-3:2011 supplements ISO 14630, which specifies general requirements for the performance of non-active surgical implants.

The following are within the scope of ISO 25539-3:2011:

  • vena cava filters used to prevent pulmonary embolism by mechanical filtration in the inferior vena cava: while ISO 25539-3:2011 might be useful with respect to filters implanted in other venous locations (e.g. superior vena cava, iliac veins), it does not specifically address use of filters in other implantation sites;
  • sheath/dilator kits, providing that they comprise an integral component of the access, delivery or retrieval/conversion of the vena cava filter.
  • delivery systems, providing that they comprise an integral component of the deployment of the vena cava filter.
  • optional filters that can be retrieved or converted, and permanent filters together with their associated endovascular systems: while ISO 25539-3:2011 might be useful with respect to the evaluation of repositioning filters after chronic implantation, it does not specifically address filter repositioning.

The following are outside the scope of ISO 25539-3:2011:

  • temporary filters (e.g. tethered) that need to be removed after a defined period of time;
  • coatings, surface modifications, and/or drugs;
  • issues associated with viable tissues and non-viable biological materials;
  • degradation and other time-dependent aspects of absorbable materials;
  • procedures and devices (e.g. venous entry needle) used prior to the vena cava filter procedure.

File Size : 1 file , 1.4 MB
Note : This product is unavailable in Ukraine, Russia, Belarus
Published : 12/01/2011
Same As : ISO 25539-3:2011

History

ISO 25539-3:2024
Published Date: 10/01/2024
Cardiovascular implants - Endovascular devices - Part 3: Vena cava filters
$83.4
ISO 25539-3:2011
Published Date: 12/01/2011
Cardiovascular implants - Endovascular devices - Part 3: Vena cava filters
$83.4

Related products

ISO 13781:2017
Published Date: 07/01/2017
Implants for surgery - Homopolymers, copolymers and blends on poly(lactide) - In vitro degradation testing
$37.2
ISO 5838-3:1993
Published Date: 09/01/1993
Implants for surgery -- Skeletal pins and wires -- Part 3: Kirschner skeletal wires
$16.2
ISO 14243-1:2009
Published Date: 11/15/2009
Implants for surgery - Wear of total knee-joint prostheses - Part 1: Loading and displacement parameters for wear-testing machines with load control and corresponding environmental conditions for test
$37.2
ISO 14630:2024
Published Date: 09/01/2024
Non-active surgical implants - General requirements
$49.8

Best-Selling Products

AS (RISSB) 1085.1:2019
Published Date: 09/25/2019
Railway Track Material, Part 1: Steel Rails
$49.5
AS (RISSB) 1085.14:2019
Published Date: 12/02/2019
Railway track material, Part 14: Prestressed concrete sleepers
$49.5
AS (RISSB) 1085.17:2021
Published Date: 06/22/2021
Railway track material, Part 17: Steel sleepers
$50.49
AS (RISSB) 1085.20:2020
Published Date: 06/23/2020
Railway track materials, Part 20: Welding of steel rail
$12.078
AS (RISSB) 1085.21:2020
Published Date: 06/23/2020
Railway track material, Part 21: Turnouts, switches and crossings
$26.532
AS (RISSB) 1085.22:2020
Published Date: 03/24/2020
Railway track materials: Alternative material sleepers
$49.5