Description:

Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 6: Wedge meters

Publisher:
International Organization for Standardization

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$33.3
Need Help?

This document specifies the geometry and method of use (installation and operating conditions) of wedge meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit.

NOTE 1 As the uncertainty of an uncalibrated wedge meter can be too large for a particular application, it could be deemed essential to calibrate the flow meter according to Clause 7.

This document gives requirements for calibration which, if applied, are for use over the calibrated Reynolds number range. Clause 7 could also be useful guidance for calibration of meters of similar design but which fall outside the scope of this document.

It also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167-1.

This document is applicable only to wedge meters in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. Uncalibrated wedge meters can only be used within specified limits of pipe size, roughness, beta (or wedge ratio) and Reynolds number. It is not applicable to the measurement of pulsating flow. It does not cover the use of uncalibrated wedge meters in pipes whose internal diameter is less than 50 mm or more than 600 mm, or where the pipe Reynolds numbers are below 1 ° 104.

NOTE 2 A wedge meter has a primary element which consists of a wedge-shaped restriction of a specific geometry. Alternative designs of wedge meters are available; however, at the time of writing there is insufficient data to fully characterize these devices, and therefore these meters are calibrated in accordance with Clause 7.


Edition : 1st
File Size : 1 file , 1.5 MB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 20
Published : 02/01/2019
Same As : ISO 5167-6:2019

History

ISO 5167-6:2022
Published Date: 09/30/2022
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 6: Wedge meters
$37.2
ISO 5167-6:2019
Published Date: 02/01/2019
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 6: Wedge meters
$33.3

Related products

ISO 20456:2017
Published Date: 09/01/2017
Measurement of fluid flow in closed conduits - Guidance for the use of electromagnetic flowmeters for conductive liquids
$58.2
ISO 8316:1987
Published Date: 10/01/1987
Measurement of liquid flow in closed conduits - Method by collection of the liquid in a volumetric tank
$49.8

Best-Selling Products

NAAMM AMP 500-06
Published Date: 01/01/2006
Metal Finishes Manual
NAAMM AMP 510-92
Published Date: 01/01/1992
Metal Stairs Manual
NAAMM AMP 521-01 (R2012)
Published Date: 01/01/2001
Pipe Railing Manual
NAAMM AMP 555-92
Published Date: 01/01/1992
Code of Standard Practice for the Architectural Metal Industry (Including Miscellaneous Iron)
NAAMM FP 1001-07
Published Date: 10/05/2007
Guide Specifications for Design of Metal Flagpoles
$9
NAAMM HMMA 850-00
Published Date: 01/01/2000
Fire Rated Hollow Metal Doors & Frames