ISO 9919:2005 PDF

ISO 9919:2005 PDF

Name:
ISO 9919:2005 PDF

Published Date:
03/15/2005

Status:
Active

Description:

Medical electrical equipment - Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use

Publisher:
International Organization for Standardization

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$60.6
Need Help?
For the purposes of ISO 9919:2005, the Scope given in IEC 60601-1:1988 (Clause 1) applies, except as follows. Amendment (add at the end of 1.1): ISO 9919:2005 specifies particular requirements for the basic safety and essential performance of pulse oximeter equipment intended for use on humans. This includes any part necessary for normal use, e.g. the pulse oximeter monitor, pulse oximeter probe, probe cable extender. These requirements also apply to pulse oximeter equipment, including pulse oximeter monitors, pulse oximeter probes and probe cable extenders, that has been reprocessed. The intended use of pulse oximeter equipment includes, but is not limited to, the estimation of arterial oxygen haemoglobin saturation and pulse rate on patients in healthcare institutions as well as on patients in home care. ISO 9919:2005 is not applicable to pulse oximeter equipment intended for use in laboratory research applications nor to oximeters that requires a blood sample from the patient. ISO 9919:2005 is not applicable to pulse oximeter equipment solely intended for fetal use. ISO 9919:2005 is not applicable to remote or slave (secondary) devices that display SpO2 values that are located outside of the patient environment. The requirements of ISO 9919:2005 which replace or modify requirements of IEC 60601-1:1988 and its Amendments 1 (1991) and 2 (1995) are intended to take precedence over the corresponding general requirements.
File Size : 1 file , 1.6 MB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 81
Published : 03/15/2005

History

ISO 80601-2-61:2017
Published Date: 12/01/2017
Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment
$83.4
ISO 80601-2-61:2011
Published Date: 04/01/2011
Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment
$69.6
ISO 9919:2005
Published Date: 03/15/2005
Medical electrical equipment - Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use
$60.6

Related products

ISO 11040-2:2011
Published Date: 04/01/2011
Prefilled syringes - Part 2: Plunger stoppers for dental local anaesthetic cartridges
$16.2
ISO 9360-2:2001
Published Date: 04/15/2001
Anaesthetic and respiratory equipment -- Heat and moisture exchangers (HMEs) for humidifying respired gases in humans -- Part 2: HMEs for use with tracheostomized patients having minimum tidal volumes of 250 ml
$24.3
ISO 4135:2022
Published Date: 02/01/2022
Anaesthetic and respiratory equipment - Vocabulary
$16.2

Best-Selling Products