JEDEC JESD 24-4 (R2002) PDF

JEDEC JESD 24-4 (R2002) PDF

Name:
JEDEC JESD 24-4 (R2002) PDF

Published Date:
11/01/1990

Status:
Active

Description:

ADDENDUM No. 4 to JESD24 - THERMAL IMPEDANCE MEASUREMENTS FOR BIPOLAR TRANSISTORS (DELTA BASE-EMITTER VOLTAGE METHOD)

Publisher:
JEDEC Solid State Technology Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$16.8
Need Help?
The purpose of this test method is to measure the thermal impedance of the Bipolar Transistor under the specified conditions of applied voltage, current and pulse duration. The temperature sensitivity of the base-emitter voltage is used as the junction temperature indicator. This test method is used to measure the thermal response of the junction to a heating pulse. Specifically, the test may be used to measure dc thermal resistance, and to ensure proper die mountdown to its case. This is accomplished through the appropriate choice of pulse duration and heating power magnitude.
File Size : 1 file , 350 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 16
Published : 11/01/1990

History


Related products

JEDEC JEP145
Published Date: 02/01/2003
GUIDELINE FOR ASSESSING THE CURRENT-CARRYING CAPABILITY OF THE LEADS IN A POWER PACKAGE SYSTEM
$15.9
JEDEC JESD302 (R2009)
Published Date: 01/01/1965
RANGES AND CONDITIONS FOR SPECIFYING BETA FOR LOW POWER, AUDIO FREQUENCY TRANSISTORS FOR ENTERTAINMENT SERVICE
$14.1
JEDEC JESD 353 (R2009)
Published Date: 04/01/1968
THE MEASUREMENT OF TRANSISTOR NOISE FIGURE AT FREQUENCIES UP TO 20 kHz BY SINUSOIDAL SIGNAL-GENERATOR METHOD
$15.3
JEDEC JESD6 (R2002)
Published Date: 02/01/1967
MEASUREMENT OF SMALL VALUES OF TRANSISTOR CAPACITANCE
$17.7

Best-Selling Products

PDA PTC PUPSIT 1
Published Date: 02/01/2020
Points to Consider for Risks Associated with Sterilizing Grade Filters and Sterilizing Filtration
$97.5
PDA PTC PUPSIT 2
Published Date: 03/01/2020
Points to Consider for Implementation of Pre-Use Post-Sterilization Integrity Testing (PUPSIT)
$97.5
PDA TR 13-2
Published Date: 11/01/2020
Technical Report No. 13-2 Fundamentals of an Environmental Monitoring Program Annex 1: Environmental Monitoring of Facilities Manufacturing Low Bioburden Products
$97.5
PDA TR 13
Published Date: 06/01/2014
Technical Report 13 Revised, (TR 13) Fundamentals of an Environmental Monitoring Program
$97.5
PDA TR 13
Published Date: 04/22/2022
Technical Report 13 Revised 2022, (TR 13) Fundamentals of an Environmental Monitoring Program
$97.5
PDA TR 14
Published Date: 09/01/2008
PDA Technical Report No. 14 (TR 14) Validation of Column-Based Chromatography Processes for the Purification of Proteins
$97.5