MODUK DEF STAN 59-113 PDF

MODUK DEF STAN 59-113 PDF

Name:
MODUK DEF STAN 59-113 PDF

Published Date:
10/14/2019

Status:
[ Active ]

Description:

Lightning Strike Protection Requirements for Service Aircraft

Publisher:
British Defence Standards

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$6.9
Need Help?

The aim of this standard is to define the design, evaluation and testing requirements, with risk assessment procedures, to be used for ensuring the safety and suitability for service of UK Military Aircraft when exposed to a lightning threat.

These Standard states the minimum requirements for the design of aircraft in order to protect them and the crew from the effects of lightning strikes. It shall apply to all fixed and rotary wing aircraft which are procured against Def Stan 00-970. It does not apply to air launched weapons and weapon systems; the requirements for which are given in NATO STANDARD AECTP-500 - Category 508 Ordnance/Munitions Verification and Testing but it does apply to the aircraft pylons and launchers.

The standard covers the cases of both a direct strike, where the lightning channel attaches to the aeroplane, and a nearby flash, where, although there is no contact, the aeroplane is near enough for it or the crew to possibly be affected by the electromagnetic fields or the aerodynamic shock wave.

Far field effects, are the effects of exposure to the radiated electromagnetic field of a distant lightning flash. The effects are not addressed in this Def Stan as protection is automatically provided by indirect effects hardening.

Direct effects arise directly from the passage of lightning current and are therefore present only in direct strikes. Possible hazards include puncture of the aeroplane skin, including that of fuel tanks, and fire or explosion due to sparking or hot spots. Indirect effects are due to coupling with the electromagnetic fields of the lightning current flowing in the aeroplane or in the lightning flash itself. These effects may therefore arise as a result of either a direct strike or a nearby flash. Possible hazards include malfunction of electronic equipment, or permanent damage to it, due to induced transient voltages or currents. Leader phase effects, such as corona or dielectric puncture, are the effects due to the high electrical stress that occurs as a lightning leader attaches to the aircraft.


Edition : I3
File Size : 1 file , 1.1 MB
Number of Pages : 92
Published : 10/14/2019

History

MODUK DEF STAN 59-113
Published Date: 10/14/2019
Lightning Strike Protection Requirements for Service Aircraft
$6.9
MODUK DEF STAN 59-113
Published Date: 10/19/2012
Lightning Strike Protection Requirements for Service Aircraft
MODUK DEF STAN 59-113
Published Date: 03/03/2006
Lightning Strike Protection Requirements for Service Aircraft

Related products

MODUK DEF STAN 02-101: PART 2
Published Date: 12/05/2005
Requirements for Design and Fitting Out of Workshops Maintenance Spaces and Engineering Stores for HM Surface Ships Part 2: Specific Requirements
$9.6
MODUK DEF STAN 21-28: PART 4
Published Date: 04/01/2000
Standard for Inter-System Communications Protocols Part 4 Rules and Protocols for the Passing of Large Blocks of Data Across Digital Highways
$6.6
MODUK DEF STAN 61-021: SUPP 017
Published Date: 01/28/2021
General Specification For Batteries Supplement: 017 : Silver Oxide Battery 4.65V NSN 6135-99-335-5022
$1.5

Best-Selling Products

ULC 101
Published Date: 07/01/2007
Standard Methods of Fire Endurance Tests of Building Construction and Materials
ULC 101
Published Date: 06/01/2014
Standard Methods of Fire Endurance Tests of Building Construction and Materials (CAN/ULC S101-14)
$77.1
ULC 102.2
Published Date: 06/01/2018
Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies
$75
ULC 102.3
Published Date: 01/01/1982
Standard Method of Fire Test of Light Diffusers and Lenses (CAN/ULC S102.3-07)
ULC 102.4
Published Date: 07/01/2010
Standard Method of Test for Fire and Smoke Characteristics of Electrical Wiring, Cables and Non-Metallic Raceways (CAN/ULC S102.4-10)
$52.8
ULC 109
Published Date: 09/01/2014
Flame Tests of Flame Resistant Fabrics and Films (CAN/ULC S109-14)
$61.5