MODUK DEF STAN 61-12: PART 5 PDF

MODUK DEF STAN 61-12: PART 5 PDF

Name:
MODUK DEF STAN 61-12: PART 5 PDF

Published Date:
09/30/2008

Status:
[ Revised ]

Description:

Wires, Cords and Cables, Electrical-Metric Units Part 5 Cables, Special Purpose, Electrical and Cables, Power, Electrical (Small Multi-Core Cables)

Publisher:
British Defence Standards

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
Need Help?
CANC NO S/S

Low tension (LT) cores of these cables are insulated with PVC and are suitable for operation up to 440 V rms at frequencies up to 1.6 kHz. High Tension (HT) cores are insulated with polyethylene and are suitable for operation up to 2000 V rms at frequencies up to 1.6 kHz.

Current carrying capacities for multi-core cables are not given owing to the varied conditions of loading and construction. However, for guidance, where a single core of a multi-core cable is loaded, the current in a 16/0.2 mm conductor should not exceed 2.5 Amps, and in a 37/0.315 mm conductor the current should not exceed 13 Amps.

The recommended maximum (conductor) operating temperature for the cables in Table 1 is 70°C but they may be operated at slightly higher temperatures for short periods. No definite limit can be given for low temperature because conditions of use are varied and include, for example, the rate of bending, the radius of bending, and the length of time the cable is exposed to the low temperature. PVC compounds become increasingly stiff and brittle as their temperature decreases, with the result that if the cable is bent too sharply or is struck sharply at temperatures lower than about 0°C there is a risk of shattering the PVC.

Although the insulation and sheath of the cables are tested in a specified manner at temperatures down to -15°C and -30°C respectively, and although in storage and when once installed, (but not subjected to flexing or severe vibration) the cables can withstand temperatures as low as -55°C, it is recommended that they should not be bent in handling unless cable and ambient temperatures are above 0°C and have been so for the previous 24-hours or unless special precautions have been taken to maintain the cable above this temperature.

The recommended maximum (conductor) operating temperature for the cables in Table 2 is 85°C and the lower test temperatures for insulation and sheath are -15° and -20°C respectively. In other respects sub-clauses 1.3 and 1.4 above apply.


Edition : I5
Number of Pages : 24
Published : 09/30/2008

History

MODUK DEF STAN 61-012: PART 05
Published Date: 03/14/2023
Wires, Cords, and Cables, Electrical - Metric Units Part: 05: Cables, Special Purpose, Electrical and Cables, Power, Electrical (Small Multi-Core Cables)
$2.1
MODUK DEF STAN 61-12: PART 5
Published Date: 09/30/2008
Wires, Cords and Cables, Electrical-Metric Units Part 5 Cables, Special Purpose, Electrical and Cables, Power, Electrical (Small Multi-Core Cables)
MODUK DEF STAN 61-12: PART 5
Published Date: 09/30/2008
Wires, Cords and Cables, Electrical-Metric Units Part 5 Cables, Special Purpose, Electrical and Cables, Power, Electrical (Small Multi-Core Cables)
MODUK DEF STAN 61-12: PART 5
Published Date: 12/23/2005
Wires, Cords, and Cables, Electrical Metric Units Part 5 Cables, Special Purpose, Electrical and Cables, Power, Electrical (Small Multi-Core Cables)
MODUK DEF STAN 61-12: PART 5
Published Date: 09/21/1981
Wires, Cords, and Cables, Electrical-Metric Units Part 5: Cables, Special Purpose, Electrical and Cables, Power, Electrical (Small Multi-Core Cables)

Related products

MODUK DEFCON 127
Published Date: 08/01/2021
Price Fixing Condition For Contracts Of Lesser Value
$0.3
MODUK DEF STAN 02-512: PART 1
Published Date: 12/21/2012
Guide to Cables, Electrical and Associated Items Part 1 General
$0.9

Best-Selling Products

FCI 13-1-2022
Published Date: 2022
Determining Condensate Loads to Size Steam Traps
$66
FCI 15-1-2020
Published Date: 2020
Standard for Production Testing of Pressure Regulators
$49.5
FCI 17-1-2018
Published Date: 10/01/2018
Standard for Production Testing of Sanitary Pressure Regulators
$33
FCI 18-1-2021
Published Date: 2021
Standard for Sizing and Selection of Type 1 Secondary Pressure Drainers
$33
FCI 18-2-2020
Published Date: 2020
Standard for Installation of Type 1 Secondary Pressure Drainers
$33