This specification covers the general requirements, property and performance requirements, quality, qualification, source approval, and quality control for six weights of polymeric sheet materials that can be used as a sound deadener coupled with an underlayment of foam or shoddy. The type of underlayment is to be specified in an appropriate specification. Other applications may include vibration dampers for treatment of vehicle substrate material.
Type I: minimum weight is 2.44 kg/m² or 0.50 Lb/ft²
Type II: minimum weight is 3.90 kg/m² or 0.80 Lb/ft²
Type III: minimum weight is 4.88 kg/m² or 1.00 Lb/ft²
Type IV: minimum weight is 6.10 kg/m² or 1.25 Lb/ft²
Type V: minimum weight is 7.81 kg/m² or 1.60 Lb/ft²
Type VI: minimum weight is 1.7 kg/m² or 0.35 Lb/ft²
Type VII: minimum weight is 1.2 kg/m² or 0.25 Lb/ft² (Door water shield applications)
Type I, II, III, IV, V, or VI Sound Deadeners will be further divided into Grade A, B, C, D, E, F or G dependent on Property and Performance values listed in Section 4.2.
Note: If Grade is not specified, then Grade A shall apply.
Restricted Chemical Substances
Effective January 1, 2007, all product supplied to the requirements of this specification must comply with the requirements of the CEMS B-50 specification.
APPLICATION
This specification covers flat or formed polymeric sheet material that is suitable as a barrier for the purpose of reduction of transmitted sound, or as an extensional (or constrained-layer) mass-damper treatment.
| Edition : | 11 |
| Number of Pages : | 6 |
| Published : | 06/01/2011 |