NFPA (Fire) 318 PDF

NFPA (Fire) 318 PDF

Name:
NFPA (Fire) 318 PDF

Published Date:
08/21/2017

Status:
Active

Description:

Standard for the Protection of Semiconductor Fabrication Facilities, 2018 Edition

Publisher:
National Fire Protection Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
Need Help?
Codes and standards published by NFPA are displayed as read-only under license from NFPA solely for use within this system. NFPA material may not be downloaded, printed, reproduced, or transferred.

Improve chemical safety and emergency response using the 2018 edition of NFPA 318: Standard for the Protection of Semiconductor Fabrication Facilities.

The semiconductor industry continues to advance, requiring new safeguards to address evolving hazards. Reorganized and with major revisions to the requirements for both gas-detection systems as well as smoke detection systems, NFPA 318: Standard for the Protection of Semiconductor Fabrication Facilities applies to semiconductor fabrication facilities and comparable R&D areas in which hazardous chemicals are used, stored, and handled -- containing a cleanroom or clean zone or both.

Chapters address every aspect of safety, from general safety precautions and fire protection to construction, chemical storage and handling, hazardous gas cylinder storage and distribution, bulk silane systems, production and support equipment, emergency control station, and means of egress.

The 2018 edition of NFPA 318 assists all stakeholders involved in fire protection: engineers, AHJs, facility personnel, and contractors.
  • Requirements for gas-detection systems as well as smoke detection systems are technically modified and also revised for clarity.
  • Gas detection criteria are revised to clarify when detection is needed and where it is required to be physically provided.
  • Requirements for detection are revised to include not just minimum capabilities of detectors but also coverage areas, alert and alarm sensitivities, and maximum transport times taken from NFPA 76: Standard for the Fire Protection of Telecommunications Facilities, which were based on research conducted by the Fire Protection Research Foundation.

ANSI : ANSI Approved
ISBN(s) : 9781455916931
Number of Pages : 44
Published : 08/21/2017

History

NFPA (Fire) 318
Published Date: 09/15/2021
Standard for the Protection of Semiconductor Fabrication Facilities, 2022 Edition
$44.7
NFPA (Fire) 318
Published Date: 08/21/2017
Standard for the Protection of Semiconductor Fabrication Facilities, 2018 Edition
NFPA (Fire) 318
Published Date: 05/19/2014
Standard for the Protection of Semiconductor Fabrication Facilities, 2015 Edition
NFPA (Fire) 318
Published Date: 06/20/2011
Standard for the Protection of Semiconductor Fabrication Facilities, 2012 Edition
NFPA (Fire) 318
Published Date: 11/07/2008
Standard for the Protection of Semiconductor Fabrication Facilities, 2009 Edition
NFPA (Fire) 318
Published Date: 09/15/2005
Standard for the Protection of Semiconductor Fabrication Facilities, 2006 edition
NFPA (Fire) 318
Published Date: 01/01/2000
Protection of Cleanrooms, 2000 Edition

Related products

NFPA (Fire) 5000
Published Date: 08/25/2023
Building Construction and Safety Code, 2024 Edition
$44.7

Best-Selling Products