NG TGN(E) 152 PDF

NG TGN(E) 152 PDF

Name:
NG TGN(E) 152 PDF

Published Date:
02/01/2012

Status:
[ Revised ]

Description:

Technical Guidance Notes - Location of Substation Sites with a Rise of Earth Potential under Fault Conditions above 650V (Hot Sites)

Publisher:
National Grid

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
ng-tgn-e-152_2814453

Choose Document Language:
0
Need Help?

PURPOSE AND SCOPE

Under power system fault conditions the substation earth (local earth) can rise to a high voltage compared to a remote earth. This phenomenon is known as Rise of Earth Potential (RoEP). Where telecommunication services are delivered to a site the RoEP can be sufficiently high to present a safety hazard both to personnel within the substation and to Public Telecommunications Operator (PTO) personnel remote from the site. A site is considered to be a ‘Hot Site' where the RoEP can rise above 430V rms or, above 650V rms for high reliability electricity transmission systems where high speed protection systems are employed. The higher voltage category applies to all the National Grid transmission system.

The International Telecommunications Union (ITU) has issued directives which recommend that protective safety measures are taken where services are delivered to Hot Sites. The Energy Networks Association has also agreed the process for managing ‘Hot Sites' with BT (refer to ENA ER S36).

This register of Hot Sites is maintained by the National Grid and is issued to PTO companies who provide telecommunication services so that appropriate measures can be taken.

At joint National Grid / Distribution Network Operator (DNO) sites, the earthing systems are normally interconnected and therefore the RoEP will be exported to the DNO site. This register is therefore also issued to DNO companies so that they are aware of the exported RoEP.


Edition : 6
Number of Pages : 12
Published : 02/01/2012

History

NG TGN(E) 152
Published Date: 09/01/2018
Technical Guidance Notes - Location of Substation Sites with an Earth Potential Rise Under Fault Conditions Above 650v (Hot Sites)
69.00 €
NG TGN(E) 152
Published Date: 09/01/2016
Technical Guidance Notes - Location of Substation Sites with an Earth Potential Rise Under Fault Conditions Above 650v (Hot Sites)
69.00 €
NG TGN(E) 152
Published Date: 09/01/2014
Technical Guidance Notes - Location of Substation Sites with an Earth Potential Rise under Fault Conditions above 650V (Hot Sites)
NG TGN(E) 152
Published Date: 02/01/2012
Technical Guidance Notes - Location of Substation Sites with a Rise of Earth Potential under Fault Conditions above 650V (Hot Sites)

Related products

NG UKBP/TP 163
Published Date: 10/01/2015
UK Business Procedure/Transmission Procedures - Site Installation
275.70 €
NG TGN(E) 182
Published Date: 06/01/2003
Technical Guidance Notes - Standard Bay Designs – Application Guidance for Connection To The Transmission System At 132 Kv, 275 Kv and 400 Kv
59.10 €
NG TS 3.03.02
Published Date: 03/01/2011
Technical Specifications - Dry-Type Reactors for AC Systems
138.00 €
NG SCT 10.01
Published Date: 11/01/1970
Site Commissioning Tests - Air Compressor Plant
55.20 €

Best-Selling Products

MHIA 10023
Published Date: 01/01/2000
Hoist Operators Manual
MHIA MH29.1
Published Date: 01/01/2003
Safety Requirements for Industrial Scissors Lifts