NR NR/L2/SIGELP/27725 ISSUE 1 PDF

NR NR/L2/SIGELP/27725 ISSUE 1 PDF

Name:
NR NR/L2/SIGELP/27725 ISSUE 1 PDF

Published Date:
03/04/2017

Status:
[ Active ]

Description:

Insulation Monitoring and Fault Location Systems for Use on Signalling Power Systems

Publisher:
Network Rail

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$18.6
Need Help?
PDF ONLY

This standard defines Network Rail’s requirements for IMDs and IFLSs for use on Isolated Terra (IT) Electrical Systems where the nominal system voltage does not exceed 1000 V a.c. or 1500 V d.c. for the following applications:

a) the interface between the Principal Supply Point (PSP)/Auxiliary Supply Point (ASP) and the Functional Supply Point (FSP);

b) the interface between an FSP and another FSP;

c) the interface points along a distribution feeder where a Distribution Interface Transformer Assembly (DITA) or Booster or Isolation Transformer has been installed;

d) Signalling Functional Circuits (a.c. and d.c.);

e) Traction derived power supplies interfacing with Principal Supply Point (PSP)/Auxiliary Supply Point (ASP);

f) Standby generator supplies interfacing with Principal Supply Point (PSP)/Auxiliary Supply Point (ASP);

NOTE 1: The nominal voltages used on SPSs are: 110 V; 230 V; 400/440 V and 650 V a.c.

The nominal voltages for Signalling Functional Circuits are typically 110/140 V a.c. 50/120 V d.c.

NOTE 2: Boundaries between subsystem elements are detailed in NR/L2/SIGELP/27416.

The following integrated systems and sub-systems are specified:

• Integrated solutions for the deployment of IMDs and IFLSs using a Tier 1, Tier 2 or Tier 3 architecture (see section 6.1);

• The interface of IMDs and IFLSs with Intelligent Infrastructure Systems.

IMDs and IFLSs as specified in this specification may also be used in other railway LV applications, e.g. car park charging points, tunnel lighting, traction transformer to PSP distribution, etc

Purpose

The purpose of this standard is to define Network Rail’s requirements for Insulation Monitoring Devices/Systems (IMDs) and Insulation Fault Location Systems (IFLSs).

This standard is one of a suite of Network Rail standards that contribute to managing the electrical and operational safety risks. Compliance with this standard will satisfy that IMDs and IFLSs are manufactured, integrated and tested in accordance with Network Rail’s requirements as defined in this document


Edition : 1
File Size : 1 file , 1000 KB
Number of Pages : 35
Published : 03/04/2017

History


Related products

NR TPWS/TGN/005 ISSUE 4
Published Date: 10/04/2001
TPWS Signal Selection in Absolute Block, Electric Token Block and Tokenless Block Areas
$18.6
NR TEF 3224 ISSUE 1
Published Date: 12/01/2011
Sperry RTS-RSU Pump Gauge Calibration Result Sheet
$5.7
NR NR/L3/OPS/045/3.17 ISSUE 3
Published Date: 06/06/2020
National Operating Procedure (NOP) 3.17: Weather Arrangements
$18.6
NR T28397 ISSUE 2
Published Date: 06/13/2008
Lineside & on Track Equipment Typical Circuits Signals & Indicators - Banner Repeater Lighting Circuit; 3-Aspect LED Type; Single; SSI
$5.7

Best-Selling Products

ALSC PS 20
Published Date: 10/01/2021
American Softwood Lumber Standard
ALSC PS 20
Published Date: 01/01/2005
American Softwood Lumber Standard
ALSC PS 20
Published Date: 06/01/2010
American Softwood Lumber Standard