NR NR/L3/TEL/30181/011 ISSUE 1 PDF

NR NR/L3/TEL/30181/011 ISSUE 1 PDF

Name:
NR NR/L3/TEL/30181/011 ISSUE 1 PDF

Published Date:
09/05/2020

Status:
[ Revised ]

Description:

Telecoms Maintenance Work Instructions Handbook: Maintenance of Operational Telephones

Publisher:
Network Rail

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$13.2
Need Help?
PDF ONLY

This instruction applies to all staff engaged in the maintenance and testing of all lineside assets (such as Signal Post Telephones, Crossing Telephones etc) and operational building telephones.

For the purposes of this instruction an operational building shall include: -  

  • Operational Control Offices  

  • Electrical Control Offices  

  • Signalling/Operating Centres (including Signal Boxes, Gate Boxes, Crossing Keepers Huts, token huts, GF huts and shunters cabins etc)  

  • Equipment Rooms (such as relay rooms, REBs etc)  

  • Electrical installations (such as Track Section Cabins, Feeder Stations, PSPs etc)

It excludes: -

  • Non-operational rooms situated in operational buildings (such as messrooms, offices etc),  

  • PETS units in Signalling/Operating Centres as defined above (this is covered under maintenance standard NR/L3/TEL/30181/013)  

  • Lineside plug points and telephones connected to Tunnel Emergency Communication Systems (this is covered under maintenance standard NR/L2/TEL/30097)  

  • GSM/GSM-R Crossing Phones (covered under standard NR/L3/TEL/30181/006)  

  • GSM-R HMI's (covered under NR/L3/TEL/30181/012)  

  • Concentrator HMI's

Purpose

This telecoms maintenance instruction defines the maintenance and functional testing that Network Rail requires for telephones used lineside and in operational buildings, which are provided to facilitate safety critical communications for the safe operation of the railway.

The purpose of maintaining and testing these telephones is to decrease the incidence of failures through deterioration and to identify potential failures before they become service affecting.

NOTE: It is the intention of Network Rail that, where practicable, deficiencies of a minor nature should be rectified during inspection.


Edition : 1
File Size : 1 file , 260 KB
Number of Pages : 17
Published : 09/05/2020

History

NR NR/L3/TEL/30181/011 ISSUE 2
Published Date: 03/05/2022
Telecoms Maintenance Work Instructions Handbook: Maintenance of Operational Telephones
$13.2
NR NR/L3/TEL/30181/011 ISSUE 1
Published Date: 09/05/2020
Telecoms Maintenance Work Instructions Handbook: Maintenance of Operational Telephones
$13.2

Related products

NR T00020 ISSUE 8
Published Date: 06/04/2022
Lineside and On-Track Equipment Typical Circuits - General Notes 1
$5.7
NR NR/L2/RSE/CONM/001/01 ISSUE 2
Published Date: 12/02/2023
Construction Management for Projects: Assurance
$7.5
NR BRS-ST 90/9 ISSUE A
Published Date: 11/01/1967
Lugs Driving Spindle Sub-Assembly Lifting Barrier (Auto) MK II B
$5.7
NR NR/L3/CIV/140/126N ISSUE 3
Published Date: 06/01/2008
Model Clause 126N: Temporary Bridges
$7.5

Best-Selling Products

PDA PTC PUPSIT 1
Published Date: 02/01/2020
Points to Consider for Risks Associated with Sterilizing Grade Filters and Sterilizing Filtration
$97.5
PDA PTC PUPSIT 2
Published Date: 03/01/2020
Points to Consider for Implementation of Pre-Use Post-Sterilization Integrity Testing (PUPSIT)
$97.5
PDA TR 13-2
Published Date: 11/01/2020
Technical Report No. 13-2 Fundamentals of an Environmental Monitoring Program Annex 1: Environmental Monitoring of Facilities Manufacturing Low Bioburden Products
$97.5
PDA TR 13
Published Date: 06/01/2014
Technical Report 13 Revised, (TR 13) Fundamentals of an Environmental Monitoring Program
$97.5
PDA TR 13
Published Date: 04/22/2022
Technical Report 13 Revised 2022, (TR 13) Fundamentals of an Environmental Monitoring Program
$97.5
PDA TR 14
Published Date: 09/01/2008
PDA Technical Report No. 14 (TR 14) Validation of Column-Based Chromatography Processes for the Purification of Proteins
$97.5