Description:

Management of Pan 8 & Lockspiked Track

Publisher:
Network Rail

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$5.7
Need Help?
INACTIVE * PDF ONLY

Introduction

The derailment at West Sutton on 9th October 2001 was due to gauge spread caused by corrosion and shearing of the lockspike fastenings installed with Pan 8 baseplates on hardwood sleepers.

The failure of the lockspike is difficult to detect as it tends to occur beneath the baseplate. Therefore the following special instructions must be applied to the management of Pan 8 and other lockspiked track.


Edition : 1
File Size : 1 file , 110 KB
Number of Pages : 5
Published : 11/16/2001

History


Related products

NR X03840 ISSUE 2
Published Date: 02/06/1999
AHBC Typical Circuits Control Circuits (1) Double Line Bi-Directional with Signal Regulation, Separate ATC and Over-Run Call by Track Circuit
$5.7
NR T28230 ISSUE 3
Published Date: 06/10/2009
Lineside & on Track Equipment Typical Circuits Signals & Indicators Auto Aspect Sequence: Entering Interlocking; Junction signal Approach Controlled from Yellow
$5.7
NR NR/L2/SIG/30014/D120/TS5-66 ISSUE 2
Published Date: 12/05/2020
Signalling Works Testing Handbook: Frauscher FAdC R1 and R2 Axle Counter Evaluator System Test Specification
$7.5
NR NR/L3/TEL/40047 ISSUE 5
Published Date: 12/04/2021
Process for the Management of Safety Related Reports for Telecoms Failures
$18.6

Best-Selling Products

SAE/ISO CRP10
Published Date: 01/01/1995
Noise Test Site Variability