NR RT/E/WI/27099 ISSUE 1 PDF

NR RT/E/WI/27099 ISSUE 1 PDF

Name:
NR RT/E/WI/27099 ISSUE 1 PDF

Published Date:
12/04/2004

Status:
[ Inactive ]

Description:

Isolation & Earthing at Hackney Downs No. 2 TSC (aka NR/WI/ELP/27099)

Publisher:
Network Rail

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$18.6
Need Help?
INACTIVE * PDF ONLY

Introduction

The following instructions apply only to the 25kV Hackney Downs No. 2 TSC. These instructions set out the procedure to be carried out in connection with the issue and cancellation of High Voltage Permits to Work or Sanctions for Test, to enable work/testing to be carried out on this equipment or the connections thereto.

This instruction shall be read in conjunction with the following documents:

a) Instructions for Making Out, Issuing and Cancelling Permits to Work, Sanctions for Test and Circuit State Certificates (BR 12011/1).

b) The Working Instructions for A.C. Electrified Lines (BR 29987).

c) Rules for Ensuring Safety with Electrical Apparatus (BR 11884).

The following abbreviations apply:

E.C.O. Electrical Control Operator

O.H.L. Overhead Line

C.B. Circuit Breaker

Before carrying out any isolation affecting normal feeding arrangements, the E.C.O. shall ensure that arrangements have been implemented for alternative feeding.

All circuit breakers and O.H.L. feeder switches shall be operated in conjunction with the E.C.O. Each step of preparatory switching shall be agreed between the E.C.O. and the Nominated Person in Charge of the isolation. Each step shall be confirmed as having taken place before the next step can be carried out. Details of Permits to Work/Sanctions for Test shall be exchanged between the Nominated Person and the E.C.O. before issue. Each party will record details onto their copy of the document.

Where the use of portable earths is specified in this document, a single portable earth is required at each point of application. The earthing requirements specified herein do not preclude the use of additional portable earths considered necessary by the Nominated Person.

External earth connections shall be connected to the external earthing bar provided. All portable earths and additional portable earths shall be applied by a BR Authorised Person.

All portable earths shall be of an approved type and applied only using an approved earthing device. When using portable earths the earth end clamp shall be connected first before use and removed last after use. All leads shall be clear of rail traffic.

After the equipment has been isolated and earthed in accordance with the following procedures and a Permit to Work has been issued, it will be necessary to apply one or more extra portable earths if the work requires the opening of a C.B. or disconnection of the busbars.

Where no separate earth electrode is installed the connection to "earth" shall be interpreted as connections to the return current busbar, station earth tape or external earth bar, which are common connected and in turn connected by two or more bonds to the adjacent traction return rail, which together with the foundations of the overhead line structures constitute an effective earth electrode.

The bus section C.B. can be isolated by means of the manual and bus section sequential isolators. All other circuit breakers are provided with external circuit isolators, in the form of overhead line feeder switches, and sequential motorised isolators.

Before access can be permitted to any 25 kV enclosure, the circuit breakers, busbars and connections within that enclosure shall be isolated from all sources of supply, and earthed externally.


Edition : 1
File Size : 1 file , 250 KB
Number of Pages : 27
Published : 12/04/2004

History


Related products

NR NR/L3/MTC/MG0213/MA184 ISSUE 1
Published Date: 12/07/2019
Number of Wire Insulation Degradation Inspections Overdue
$5.7
NR NR/L3/OCS/044/MS-01 ISSUE 3
Published Date: 06/04/2011
Managed Station Manual: Planned General Inspections
$7.5
NR BRS-SM 571/3 ISSUE B
Published Date: 02/22/1994
Swing Nose Crossing Keeper Bar for Drive Lock Mechanism
$5.7
NR X70170 ISSUE 4
Published Date: 04/07/2007
MCB Typical Circuits Road Light Circuits (1) (Tungsten Halogen Lamps)
$5.7

Best-Selling Products

AGA A25023
Published Date: 01/01/2005
2005 Handbook of Publicly Traded AGA Member Companies
$57
AGA A25024
Published Date: 01/01/2006
2006 Handbook of Publicly Traded AGA Member Companies
$57
AGA ANSI Z223.1-2024 / NFPA 54
Published Date: 2024
National Fuel Gas Code, 2024 Edition
$28.2
AGA ANSI Z223.1 Set
Published Date: 01/01/2002
National Fuel Gas Code and Handbook Set, 2002 Edition
AGA ANSI Z223.1 Set
Published Date: 01/01/2006
National Fuel Gas Code and Handbook Set, 2006 Edition
AGA ANSI Z223.1 Set
Published Date: 2009
National Fuel Gas Code and Handbook Set, 2009 Edition
$49.5