3011 -- A Comparison of Building Thermal Performance Models Using Measured Data PDF

3011 -- A Comparison of Building Thermal Performance Models Using Measured Data PDF

Name:
3011 -- A Comparison of Building Thermal Performance Models Using Measured Data PDF

Published Date:
1986

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Three different types of building thermal performance models are compared: dynamic, steady-state submeter, and steady-state utility bill level. Corresponding to these are three models in common usage in the field : the equivalent thermal parameters approach (ETP), the Buildings Energy-Use Compilation and Analysis method (SUBMET), and the Princeton Scorekeeping Method (PRISM). The models are applied to data from a subset of passive solar houses from the SERI Class B project . The ten houses used are located in the Northeast, Southeast, Midwest, and West, are all served by electric resistance heating, and have crawlspace or slab-ongrade ground coupling . The data include hourly values for indoor and outdoor temperatures, solar radiation, and energy inputs for heating, domestic hot water, and appliances. These data are aggregated according to the needs of the particular model used . The derived parameters compared include an overall building load coefficient, balance temperature, baseload, thermal capacity, time constant, and equivalent south-facing window area. Model results show fairly good agreement among parameter estimates, especially for houses located in colder regions . The errors associated with the parameters are generally larger in warmer climates. Heat loss coefficients determined by an in situ method (called "co-heating" were consistently higher than those from the models studied. The building time constant was a more reasonable indicator of building thermal inertia characteristics than the thermal capacitance . Equivalent south-facing window areas average only about one-third of the actual amount.

Units: SI

 


File Size : 1 file , 1.6 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 13
Product Code(s) : D-PO-86-3011
Published : 1986

History


Related products


Best-Selling Products

IEC/TS 60034-16-2 Ed. 1.0 b:1991
Published Date: 02/15/1991
Rotating electrical machines - Part 16: Excitation systems for synchronous machines - Chapter 2: Models for power system studies
$33
IEC/TS 60034-16-3 Ed. 1.0 b:1996
Published Date: 02/14/1996
Rotating electrical machines - Part 16: Excitation systems for synchronous machines - Section 3: Dynamic performance
$43.5
IEC/TS 60034-17 Ed. 3.0 b:2002
Published Date: 03/26/2002
Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide
$18.3
IEC/TS 60034-17 Ed. 4.0 b:2006
Published Date: 05/09/2006
Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide
$47.1
IEC/TS 60034-18-32 Ed. 1.0 b:1995
Published Date: 03/29/1995
Rotating electrical machines - Part 18: Functional evaluation of insulation systems - Section 32: Test procedures for form-wound windings - Electrical evaluation of insulation systems used in machines up to and including 50 MVA and 15 kV
$18.3
IEC/TS 60034-18-33 Ed. 1.0 b:1995
Published Date: 03/29/1995
Rotating electrical machines - Part 18: Functional evaluation of insulation systems - Section 33: Test procedures for form-wound windings - Multifactor functional evaluation - Endurance under combined thermal and electrical stresses of insulation systems used in machines up to and including 50 MVA a
$32.1