3526 --Performance Degradation On-Off Cycling of Single-Speed Heat Pumps Operating in the Cooling Mode - Experimental Results PDF

3526 --Performance Degradation On-Off Cycling of Single-Speed Heat Pumps Operating in the Cooling Mode - Experimental Results PDF

Name:
3526 --Performance Degradation On-Off Cycling of Single-Speed Heat Pumps Operating in the Cooling Mode - Experimental Results PDF

Published Date:
1991

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Much of the seasonal cooling operation of a heat pump occurs at part-load conditions when the unit must cycle on and off to meet the cooling load. The loss in efficiency due to cycling is estimated using the degradation coefficient, CD. CD is estimated from cycling measurements made at one condition in the laboratory. A series of tests were designed to quantify the part-load performance of a three-ton heat pump operating in the cooling mode. The tests include cycling rates from 0.8 to 10 cycles per hour (cph) and percent on-times of 20%, 50%, and 80%. The indoor and outdoor conditions were constant for all test runs. All experiments were performed in psychrometric chambers. Results indicated that the part-load factor (PLF) can be as low as 0.65 at low percent on-times and high cycling rates. It took between 6 to 15 minutes for the system to reach steady state, depending on the operating conditions. The dehumidification process started between 60 and 150 seconds after start-up, depending on the test conditions. A single-time-constant model developed in a previous study was used to compare results from the experimental measurements. Results from the model showed the same trends as the experimental data. The model overpredicted losses at 4 cph and underpredicted losses at 1.2 cph.

KEYWORDS: performance, efficiency, heat pumps, speed, calculating, measuring, testing, cooling, cyclic, cooling load, factors, part load, comparing, operations, indoor, outdoor, experiment, psychrometry


File Size : 1 file , 1 MB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-18063
Published : 1991

History


Related products


Best-Selling Products

ISTA 2A
Published Date: 01/01/2008
ISTA Preshipment Testing Procedures - Combination Tests for packaged-products weighing 150 lbs. (68kg) or less
ISTA 2A
Published Date: 2011
Packaged-products weighing 150 lbs. (68kg) or less (Editorial Change, 2012)
$28.5
ISTA 2B
Published Date: 2011
Packaged-products weighing over 150 lbs. (68kg) (Editorial Change, 2012)
$28.5
ISTA 2C
Published Date: 2011
Furniture Packages (Editorial Change, 2012)
$28.5
ISTA 3A
Published Date: 02/01/2008
Packaged-Products for Parcel Delivery System Shipment 70 kg (150 lb) or Less (Editorial Change, 2016)
$28.5
ISTA 3A
Published Date: 03/01/2018
Packaged-Products for Parcel Delivery System Shipment 70 kg (150 lb) or Less
$28.5