3553 -- Investigating the Causes of Water Hammer in a Water Control Valve PDF

3553 -- Investigating the Causes of Water Hammer in a Water Control Valve PDF

Name:
3553 -- Investigating the Causes of Water Hammer in a Water Control Valve PDF

Published Date:
1992

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Investigates a water flow control valve. The flow rate of the water is regulated by the pressure of a stationary fluid acting on a bellows connected to the valve stem. A typical application of these valves is to control the water flow through a water-cooled refrigerant condenser in a refrigeration system, using the refrigerant pressure to regulate the water flow rate. In some valves, an effect known as "water hammer" occurs when the refrigerant pressure is in a certain range. Water hammer is a series of sonic shocks produced by suddenly reduced liquid flow in rigid (metal) pipes (Avallone and Baumeister 1978). Water hammer manifests itself by a low-frequency oscillation of the valve stem. The result of the water hammer is a very noisy valve and a pulsating water flow. The dynamic behaviour of a system consisting of the valve and the upstream and downstream connecting pipes is analysed using a finite time step approach. The analysis was written into a Fortran computer program to compute the valve gap, flow rate, and pressures in the system. From the simulation, it was found that the relationship between the friction factor and the Reynolds number for the flow through the valve gap has a significant effect on the results. Based on these results and experimental data, it appears that for valves exhibiting water hammer, the flow through the valve gap is marked by abrupt changes from laminar to turbulent flow. Three different possible design modifications that may reduce or eliminate the water hammer are presented. By changing the dimensions of the valve, the water flow in the valve gap should be in a different Reynolds number range. The second alternative is to attempt to change the flow characteristic around the circumference of the valve gap. Finally, introducing more damping will prevent the oscillations associated with water hammer.

KEYWORDS: water hammer, fluid flow, valves, water flow, refrigeration, condensers, water cooled condensers, regulating, computer programs, calculating, Reynolds numbers


File Size : 1 file , 880 KB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-17740
Published : 1992

History


Related products


Best-Selling Products

NSC 373-2013e
Published Date: 03/10/2014
Sustainability Assessment - Natural Dimension Stone
NSC 373 Chain of Custody Standard
Published Date: 03/24/2014
NSC (Safety) 023160000
Published Date: 01/01/2010
Injury Facts Book
$24.9
NSC (Safety) 062060000
Published Date:
Protecting Workers' Lives: A Safety and Health Guide for Unions
$45.3
NSC (Safety) 120270000
Published Date:
OSHA Inspections: Preparation and Response
$74.4
NSC (Safety) 120760000
Published Date:
Beyond Workers' Comp: A Human Resources Guide to Building Safety into Your Organization
$17.4