3556 (RP-527) -- Properties of Lithium Bromide-Water Solutions at High Temperatures and Concentrations - Part 3: Specific Heat PDF

3556 (RP-527) -- Properties of Lithium Bromide-Water Solutions at High Temperatures and Concentrations - Part 3: Specific Heat PDF

Name:
3556 (RP-527) -- Properties of Lithium Bromide-Water Solutions at High Temperatures and Concentrations - Part 3: Specific Heat PDF

Published Date:
1992

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

As part of ASHRAE research project 527, the heat capacity of lithium bromide and water solutions has been measured over the nominal range of 100 deg C to 200 deg C and 45% to 65% LiBr by mass. The measurements were done by the classic "method of mixing" implemented with a drop calorimeter. From tests using water as a standard reference substance and allowing for the accuracy with which the solutions can be compared, the ultimate accuracy of this procedure is estimated to be +/- 1.2%. Practical effects degrade the accuracy somewhat, and for the entire series of measurements the accuracy of the data is estimated to be +/- 5%. The resulting data agree well within three sets of measurements by other investigators but disagree substantially with two older data sets. A polynominal regression model is presented to represent the data in practical calculations.

KEYWORDS: properties, lithium bromide, water, solutions, high temperature, specific heat, measuring, accuracy, calorimeters, calculating


File Size : 1 file , 1.5 MB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-17745
Published : 1992

History


Related products


Best-Selling Products

CTI 105-ATC (00)
Published Date: 02/01/2000
CTI Code Tower Standard Specifications for Acceptance Test Code for Water Cooling Towers
$31.2
CTI 105 S (11)
Published Date: 07/01/2011
Supplement to CTI Code Tower Standard Specifications for Acceptance Test Code for Closed Circuit Cooling Towers
$10.5
CTI 105 S (96)
Published Date: 07/01/1996
CTI Code Tower Standard Specifications for Acceptance Test Code for Closed Circuit Cooling Towers
$10.5
CTI 106-ATC (04)
Published Date: 07/01/2004
Acceptance Test Code for Mechanical Draft Evaporative Vapor Condensers
$10.5
CTI ATC-105 (19)
Published Date: 02/01/2019
Acceptance Test Code For Cooling Towers
$37.5
CTI ATC-106 (11)
Published Date: 07/01/2011
Acceptance Test Code for Mechanical Draft Evaporative Vapor Condensers
$7.5