Heat recovery from an air conditioner by thermosiphon is attractive because it eliminates the need for a circulating pump. Experiments indicate the cooling capacity of the air conditioner is only marginally affected, but the compressor works a little harder, giving a slightly lower coefficient of performance. The small buoyancy-induced flow of the heated water when stored in a storage tank may be sufficient for supplying domestic hot water demand. The induced flow is, however, strongly dependent not only on the amount of heat recovered from the refrigerant but also on the heat transfer characteristics, thermal capacities, height and relative location of the tank, heat exchanger, and connecting pipes. A simple computer model is developed to predict the heating of the water in the tank as a result of the thermosiphon effect. Results of the model compare favourably with experimental data.

KEYWORDS: heat recovery, thermosiphon, unit air conditioners, domestic, hot water supply, experiment, coefficient of performance, refrigerants, heat flow, properties, computer programs, models, calculating, heating, tanks.


File Size : 1 file , 540 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 6
Product Code(s) : D-17646
Published : 1993

History


Related products


Best-Selling Products

BICSI 001-2017 R22
Published Date: 01/01/2017
Information and Communication Technology Systems Design and Implementation Best Practices for Educational Institutions and Facilities
$28.5
BICSI 002-2019
Published Date: 05/01/2019
Data Center Design and Implementation Best Practices
$157.5
BICSI 002-2024
Published Date: 05/01/2024
Data Center Design and Implementation Best Practices
$157.5
BICSI 003-2024
Published Date: 02/29/2024
Building Information Modeling (BIM) Practices for Information Communication Technology Systems
$31.5
BICSI 004-2018
Published Date: 03/01/2018
Information Technology Systems Design and Implementation Best Practices for Healthcare Institutions and Facilities
$64.5
BICSI 006-2020
Published Date: 11/25/2019
Distributed Antenna System (DAS) Design and Implementation Best Practices
$67.5