Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Single-tube spray evaporation experimental tests were conducted in order to evaluate the average wall heat transfer coefficients for seven different commercially available tubes. Liquid film supply rates were held constant in order to evaluate the effects of the enhancement on shelf-side heat transfer under similar conditions. Because the spray evaporation phenomenon is so different from pool boiling, both condensation-type and evaporation-type enhanced surfaces were evaluated. A comparison of the results for all of the tubes showed that the enhanced condensation surfaces performed better than the enhanced boiling surfaces. In addition the 26-fpi surface tested marginally better than the 40-fpi surface. Small concentrations of a polyol-ester lubricant cause a foaming effect that increases the heat transfer performance. This tendency was seen with both 32-cs and 68-cs polyol-ester oils. The 68-cs lubricant was tested at concentrations of 0.0, 0.5, 1.0, 3.0, and 5.0 with the W-40 fpi and Tu-Cii surfaces. Results with this lubricant show the performance continues to increase through the 3% concentration for most of the heat flux range tested. At the upper end of the range tested the 1.0% mass fraction yielded the best performance. The 32-cs lubricant generated trends similar to those of the 68-cs lubricant. Lubricant concentrations of 1.0%, 2.0% and 3.0% were evaluated with plain, W-40 fpi, and Tu Cii surfaces. The 2.0% concentration, not the 1.0%, generated the best performance at the highest heat flux tested. This difference must be attributed to the difference in the lubricant viscosity.

KEYWORDS: year 1995, heat flow, R134a, refrigerants, lubricants, tubes, evaporation, sprays, evaporators, performance, testing, heat transfer coefficient, comparing, copper, viscosity


File Size : 1 file , 1000 KB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-16688
Published : 1995

History


Related products


Best-Selling Products

MHI CMAA 70
Published Date: 01/01/2015
Specification for Top Running Bridge and Gantry Type Multiple Girder Electric Overhead Traveling Cranes
$37.8
MHI CMAA 70
Published Date: 01/01/2020
Specification for Top Running Bridge and Gantry Type Multiple Girder Electric Overhead Traveling Cranes
$45
MHI CMAA 74
Published Date: 01/01/2020
Specifications for Top Running and Under Running Single Girder Electric Traveling Cranes Utilizing Under Running Trolley Hoist
$45
MHI CMAA 74
Published Date: 01/01/2015
Specification for Top Running and Under Running Single Girder Electric Overhead Cranes Utilizing Under Running Trolley Hoist
$37.8
MHI CMAA 78
Published Date: 01/01/2014
Standards and Guidelines for Professional Services Performed On Overhead and Traveling Cranes and Associated Hoisting Equipment (Revised 2015)
$14.4
MHI CMAA 79
Published Date: 01/01/2012
Crane Operator's Manual
$5.4