3861 -- A Theory for Heat Exchangers with Liquid-Desiccant-Wetted Surfaces PDF

3861 -- A Theory for Heat Exchangers with Liquid-Desiccant-Wetted Surfaces PDF

Name:
3861 -- A Theory for Heat Exchangers with Liquid-Desiccant-Wetted Surfaces PDF

Published Date:
1995

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The theory extends the wet surface model of Maclaine-Cross and Banks (1981) to include heat exchangers that heat or cool moist air with liquid-desiccant-wetted surfaces. The theory uses a wall boundary condition that forces the moist air to be at an arbitrary relative humidity that is less than totally saturated. The theory defines a new temperature scale (brine-bulb temperature) for which the wet-bulb temperature is a special case. Brine-bulb heat capacitance and heat transfer coefficient are defined. By using an analogy to the dry surface heat exchanger theory, the performance of these heat exchangers can then be estimated from the performance of geometrically identical heat exchangers with a dry surface. Charts to utilise the theory at various elevations are shown.

KEYWORDS: year 1995, heat exchangers, desiccants, liquids, surfaces, wet, heating, cooling, relative humidity, brine, temperature, wet bulb temperature, comparing, heat transfer coefficient, performance, calculating, heat flow, cross flow heat exchangers


File Size : 1 file , 770 KB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-16735
Published : 1995

History


Related products


Best-Selling Products

IEC/TR 60034-16-2 Ed. 1.0 b:1991
Published Date: 02/15/1991
Rotating electrical machines - Part 16: Excitation systems for synchronous machines - Chapter 2: Models for power system studies
$88.746
IEC/TR 60068-3-12 Ed. 2.0 b:2014
Published Date: 10/17/2014
Environmental testing - Part 3-12: Supporting documentation and guidance - Method to evaluate a possible lead-free solder reflow temperature profile
$39.9
IEC/TR 60068-3-12 Ed. 3.0 en:2022
Published Date: 10/01/2022
Environmental testing - Part 3-12: Supporting documentation and guidance - Method to evaluate a possible lead-free solder reflow temperature profile
$83.4
IEC/TR 60068-3-15 Ed. 1.0 en:2024
Published Date: 02/01/2024
Environmental testing – Part 3-15: Supporting documentation and guidance – Vacuum-assisted reflow soldering
$70.2
IEC/TR 60068-3-82 Ed. 1.0 en:2024
Published Date: 08/01/2024
Environmental testing – Part 3-82: Supporting documentation and guidance – Confirmation of the performance of whisker test method
$115.8
IEC/TR 60071-4 Ed. 1.0 en:2004
Published Date: 06/23/2004
Insulation co-ordination - Part 4: Computational guide to insulation co-ordination and modelling of electrical networks
$136.5