3884 -- Prediction of Room Thermal Response by CFD Technique with Conjugate Heat Transfer and Radiation Models PDF

3884 -- Prediction of Room Thermal Response by CFD Technique with Conjugate Heat Transfer and Radiation Models PDF

Name:
3884 -- Prediction of Room Thermal Response by CFD Technique with Conjugate Heat Transfer and Radiation Models PDF

Published Date:
1995

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Since room air distribution is not uniform in most cases, the thermal comfort parameters measured by a sensor, which is often outside the occupied zone, are different from those in the occupied zone. It is necessary to identify a suitable position for the sensor and to find the correlation of the comfort parameters between the sensor zone and the occupied zone. A flow model, a conjugate heat transfer model, and a radiation model are solved simultaneously in a computational fluid dynamics (CFD) program. For a room with natural convection, the room thermal response and indoor air distribution can be computed with only the outdoor air temperature, solar radiation and indoor heat sources as the thermal boundary conditions. The agreement is very good between the computational results and the experimental data. With the thermal response and air distribution computed, the most suitable position for the sensor can be found and the correlation can be determined. Measures used to reduce the computing cost are also discussed.

KEYWORDS: year 1995, heat flow, rooms, calculating, thermal comfort, measuring, sensors, location, computer programs, room temperature, air distribution, thermal insulation, thermal conductivity, temperature distribution, thermal properties


File Size : 1 file , 1.2 MB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-16875
Published : 1995

History


Related products


Best-Selling Products

UNE-CLC/TS 50131-2-2:2005 V2
Published Date: 09/14/2005
Alarm systems - Intrusion systems -- Part 2-2: Requirements for passive infrared detectors
UNE-CLC/TS 50131-2-3:2005 V2
Published Date: 09/14/2005
Alarm systems - Intrusion systems -- Part 2-3: Requirements for microwave detectors
UNE-CLC/TS 50131-2-4:2005 V2
Published Date: 09/14/2005
Alarm systems - Intrusion systems -- Part 2-4: Requirements for combined passive infrared and microwave detectors
UNE-CLC/TS 50131-2-5:2005 V2
Published Date: 09/14/2005
Alarm systems - Intrusion systems -- Part 2-5: Requirements for combined passive infrared and ultrasonic detectors
UNE-CLC/TS 50131-2-6:2005 V2
Published Date: 09/14/2005
Alarm systems - Intrusion systems -- Part 2-6: Requirements for opening contacts (magnetic)
UNE-CLC/TS 50131-3:2005 V2
Published Date: 09/14/2005
Alarm systems - Intrusion systems -- Part 3: Control and indicating equipment