3916 (RP-668) -- Effects of Surface Enhancement, Film-Feed Supply Rate, and Bundle Geometry on Spray Evaporation Heat Transfer Performance PDF

3916 (RP-668) -- Effects of Surface Enhancement, Film-Feed Supply Rate, and Bundle Geometry on Spray Evaporation Heat Transfer Performance PDF

Name:
3916 (RP-668) -- Effects of Surface Enhancement, Film-Feed Supply Rate, and Bundle Geometry on Spray Evaporation Heat Transfer Performance PDF

Published Date:
1995

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Testing was conducted with R134a through an overfeed ratio range of 1.4 to 7.9 in order to evaluate the effects of Reynolds number on shell-side heat transfer performance in the spray evaporation environment. The overfeed ratio is defined as the ratio of the refrigerant flow rate supplied to the tube bundle to the refrigerant flow rate that vaporises. Data were taken with a fixed refrigerant supply rate while varying the shell-side heat flux from 40 kW/m2 (12,688 Btu/[h×ft2]) to 19 kW/m2 (6,027 Btu/[h×ft2]). Both triangular and square-pitch tube bundles were tested to determine the effects of bundle geometry on heat transfer performance. Two enhanced condensation surfaces, one enhanced boiling surface, and one low-finned surface tube were used in this study. Plain-surface bundle testing was conducted in parallel with the enhanced surface testing to determine the degree of improvement obtained with the different surface enhancements relative to that of a smooth tube. In addition, the effect of bundle depth on heat transfer performance was evaluated. Refrigerant was introduced into the test section with wide-angle, solid-cone nozzles. To determine the amount of refrigerant contacting the tube bundle, collector testing was performed in parallel with the heat transfer analysis experiments. Using results from the collector tests, bundle overfeed ratios were calculated and are reported. Heat transfer performance showed dependence on film-feed supply rate (i.e., overfeed ratio) to varying degrees, depending on the type of surface enhancement. Those surfaces that limited axial flow of the liquid film yielded poor heat transfer performance in lower rows of the bundle. The spray evaporation heat transfer performance for one of the enhanced condensation surfaces was better than the flooded evaporator performance for the enhanced boiling surface.

KEYWORDS: year 1995, evaporators, refrigerants, fluid flow, testing, heat flow,performance, tubes, R134a, Reynolds numbers, geometry, finned tubes, comparing


File Size : 1 file , 1.3 MB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-17119
Published : 1995

History


Related products


Best-Selling Products

SDI 106-99
Published Date: 01/01/1999
Recommended Standard Door Type Nomenclature
SDI 108-10
Published Date: 2010
Recommended Selection and Usage Guide for Standard Steel Doors
SDI 108
Published Date: 01/01/1990
Recommended Selection and Usage Guide for Standard Steel Doors
SDI 109
Published Date: 01/01/1988
Hardware for Standard Steel Doors and Frames
SDI 110-09
Published Date: 2009
Standard Steel Doors and Frames for Modular Masonry Construction
SDI 110
Published Date: 01/01/1984
Standard Steel Doors and Frames for Modular Masonry Construction